SERVICE

RADIANT STEAKHOUSE BROILER

SERVICE

TROUBLESHOOTING WARNING

ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE OF, THE OPERATION OF COMMERCIAL COOKING EQUIPMENT. TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.

NOTICE

INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY ON THIS EQUIPMENT.

The serial plate is located in the rear right corner (see Figure 1 on page 3).

Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized Parts Distributor or a Southbend Authorized Service Agency.

When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.

TROUBLESHOOTING

Problem

Look for -

 

 

Not enough heat

– Low pressure in gas supply

 

– Restriction in gas piping and/or valves

 

– Misalignment of orifice to burner venturi

 

– Clogged burner orifice

 

– Incorrect burner orifice

 

 

Too much heat

– Incorrect orifices

 

– Malfunctioning or incorrectly set pressure regulator

 

 

Burner flame has excessive yellow tipping

– Obstruction of combustion-air intake on rear of broiler

 

– Exhaust gases blocked by objects sitting on top of broiler

 

– Low pressure in gas supply

 

– Misalignment of orifice to burner venturi

 

 

Burner flame fluttering

– Low gas pressure or obstruction in orifice

 

 

Burner flame lifting

– High gas pressure or air shutter on venturi out of adjustment

 

 

Slow burner ignition

– Pilot flame out of adjustment

 

 

Pilot outage

– Pilot flame out of adjustment

 

– Draft condition

 

– Pilot orifice clogged

 

 