Troubleshooting Procedures

Troubleshooting Procedures

"PLEASE TOUCH TIME OF DAY"

does not appear in

the display,

when unit is plugged in.

1.Check power supply.

16021668 Rev. 02. Check fuse.

3.Check oven thermostat.

Measure voltage

between pin 1 and pin 3 of CN1 connector

 

YES

Is 120 volts

Replace

indicated.

circuit

 

board.

NO

 

Verify proper

 

connection of

Unit operates.

circuit board.

 

Display does not

indicate correct number

pressed or correct

indication when

programmed.

Measure resistance

Manual background of control key panel after removing

ribbon connector.

Key pad matrix is located in “Testing Procedures” on page 11.

Is continuity

 

Verify proper

 

indicated when

 

 

 

connection of

 

key pad is

 

 

YES

ribbon

 

pressed.

 

 

connector.

 

 

 

Does ribbon

NO

 

 

 

 

connector have

 

 

NO

 

 

proper

 

 

 

connection.

Replace

 

 

YES

control

 

Reconnect

 

key pad.

 

 

 

ribbon connector

 

 

 

for proper

Replace

 

 

connection.

circuit

 

 

 

board.

Unit operates.

 

 

 