Sprint Nextel DVP 203, DVP 403 quick start Protegé CTX/MTX/LTX

Models: DVP 403 DVP 203

1 22
Download 22 pages 47.9 Kb
Page 17
Image 17

Chapter 3: Getting the Voice Mail System Up and Running

STEP 7

Program the

Protegé® Phone System for Voice Mail

Certain functions in the phone system require specific programming entries when integrated with Sprint® Digital Voice.

Note: If using a phone system other than Protégé, refer to the Release Notes for Software Versions and the Integration Guide for further options.

Protegé® 3x8

When installing Sprint Digital Voice on a Protegé 3x8 system, the following settings must be changed on the phone system through the System Administrator’s mailbox using a display keyset.

Extension – Ring Assignment: Under Extension change Ring Assignment for all voice mail ports to NO. At default on the 3x8 system all extensions are assigned to ring for all lines in Day Mode operation. If the voice mail ports’ ring assignments are YES, then all voice mail ports will answer incoming calls simultaneously.

Trunkline – Voice Mail Group Answer: Program Voice Mail Group Answer to allow ring in to the Automated Attendant based on the time of day when the Auto Attendant should answer. If no Automated Attendant is used, the field should be set to NEVER. The other valid entries are ALWAYS, DAY or NIGHT.

Call Handling – Voice Mail Dialing Ratio: Set both the Tone Time and

Int_Dgt Time to 90.

Control – Voice Mail: Program all of the fields in this category as follows: VM Group Member – enter all the voice mail extensions that are used. Prefix Codes – ICM/VM: 12

Transfer: 11

Busy FWD: 11

No Ans: 11

Direct FWD: 11

Suffix Code – NULL Disconnect Digits - 999999

Protegé CTX/MTX/LTX

When installing Sprint Digital Voice on a Protegé CTX, MTX or LTX system, the following settings must be changed through Remote Maintenance Programming. Once the changes are complete, connect a laptop to the Protegé system and send the updated information.

RMP-Programming-Extension-Category 3: Mark all ports that are connected to Sprint Digital Voice as V.M. The last column on the right specifies the port type. To change a type, press e until V.M. is displayed in the field. Exit the screen and Save.

RMP-Programming-CallHandling-Voice Mail Function: Using the Down Arrow, highlight the Disconnect Codes field and enter six of the number nine (9). Exit the screen and Save.

RMP-Programming-Extension Application- Uniform Call Distribution- UCD Settings: Enter the number of the UCD hunt group that will be used as the voice mail hunt group and press e. From the Parameter

Issue 1.6

Getting the Voice Mail System Up and Running – – 13

Page 17
Image 17
Sprint Nextel DVP 203, DVP 403 quick start Protegé CTX/MTX/LTX