SPX Cooling Technologies Marley MD specifications MD5016PAC2L

Models: Marley MD

1 40
Download 40 pages 61.95 Kb
Page 17
Image 17

Marley / MD CoolingTower / Engineering Data : Schematic

17

MD5016 TWO OR THREE CELL

 

 

 

dBA

 

Dimensions

Design

Shipping Weight

Model

Nominal Tons

Motor

 

Operating

 

kg

1.5m from air

 

 

 

 

note 2

note 3

kW

 

 

 

Weight

 

 

Heaviest

inlet face

H

 

A

Weight/Cell

 

 

 

 

 

kg

 

Section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016PAC2L

317

11

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016PLC2L

320

11

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016QAC2L

345

15

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016QLC2L

348

15

79

4547

 

2837

5860

3279

 

1710

 

 

 

 

 

 

MD5016RAC2L

369

18.5

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016RLC2L

372

18.5

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016SAC2L

390

22

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016SLC2L

394

22

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016PAD2L

350

11

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016PLD2L

353

11

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016QAD2L

383

15

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016QLD2L

384

15

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016RAD2L

410

18.5

80

4852

 

3142

6143

3563

 

1800

 

 

 

 

 

 

MD5016RLD2L

412

18.5

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016SAD2L

436

22

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016SLD2L

437

22

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016TAD2L

475

30

82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016TLD2L

471

30

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016PAF2L

368

11

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016PLF2L

370

11

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016QAF2L

403

15

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016QLF2L

401

15

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016RAF2L

431

18.5

80

5156

 

3447

6375

3794

 

2032

 

 

 

 

 

 

MD5016RLF2L

431

18.5

79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016SAF2L

460

22

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016SLF2L

459

22

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016TAF2L

500

30

82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5016TLF2L

493

30

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

1Use this bulletin for preliminary layouts only. Obtain current drawings from your Marley sales representative. All table data is per cell.

2Last two characters of the model number indicate number of cells and cell configuration. Change as appropriate for your selection.

3Nominal tons are based upon 35°C HW, 29.5°C CW, 25.5°C WB and .68 m3/hr per ton. The Marley UPDATE web-based selection software provides MD model recommendations based on specific design requirements.

4Standard overflow is a 3" dia. M connection located on the side of the collection basin. Makeup water connection is 2" dia. M connection located on the side of the tower. A 3" M drain connection is located on the side of the collection basin.

Page 17
Image 17
SPX Cooling Technologies Marley MD specifications MD5016PAC2L

Marley MD specifications

SPX Cooling Technologies has long been recognized as a leader in the cooling systems industry, and the Marley MD series exemplifies this commitment to innovation and efficiency. The Marley MD line is engineered for performance and versatility, ideal for a wide range of industrial and commercial cooling applications.

One of the defining features of the Marley MD is its advanced, modular design. This modular approach allows for easy scalability, enabling users to customize their cooling solution based on specific operational needs. Each unit can be configured to meet varying cooling loads, making the Marley MD suitable for both small and large facilities.

The Marley MD utilizes state-of-the-art materials, promoting durability and longevity. Constructed with corrosion-resistant components, these units are designed to withstand harsh environmental conditions, ensuring reliable operation over extended periods. The casing often features a combination of high-quality steel and advanced coatings that provide protection against the elements, which is especially important for outdoor installation.

Additionally, the Marley MD incorporates innovative technologies such as drift eliminators and splash bars, which significantly enhance water efficiency. These features minimize water loss and reduce the risk of contaminants entering the cooling system, leading to better overall performance. The design is also optimized for low sound levels, making these systems suitable for use in sensitive environments where noise reduction is a priority.

Energy efficiency is a critical characteristic of the Marley MD. It leverages advanced fan technology and airflow management to enhance cooling performance while minimizing energy consumption. By using high-efficiency motors and variable-speed drives, the Marley MD can operate at optimal levels under varying load conditions, resulting in significant energy savings over traditional cooling systems.

Another vital aspect is the ease of maintenance. The Marley MD is designed for straightforward access, allowing for efficient servicing and reducing downtime during maintenance activities. Features like removable panels and accessible components ensure that technicians can perform routine checks and repairs quickly and efficiently.

In conclusion, the Marley MD by SPX Cooling Technologies stands out due to its modular design, durable construction, advanced water management technologies, energy efficiency, and ease of maintenance. These characteristics make it an excellent choice for any facility looking to optimize its cooling operations while ensuring reliable and sustainable performance.