5.6.5Water Temperature

Allows selection between the temperature sensor in the depth transducer and an external temp sensor connected to the Optional Connection wires.

5.7TRANSDUCER SETUP

This menu allows you to calibrate the speed through the water, water temperature and the keel/prop offset of the transducer.

Figure 5.7 - Transducer Setup menu

5.7.0Keel Offset

The keel offset can be set as to cause the Fish Finder to display an offset depth below the keel or the actual water depth from the surface. To setup to show the depth below the keel, enter a negative depth value or a positive depth to show offset from the transducers face to the water surface.

5.7.1Calibrate Water Speed

Used to calibrate the Water Speed readings from the transducer. Adjustment can be made from -10% to +10%.

5.7.2Calibrate Water Temp

Used to calibration on the Water Temperature sensor in the transducer.

5.7.3Calibrate Aux Temp

Allows the calibration of the Aux Temperature sensor connected to the Optional Connection wires.

5.7.4Set Defaults

Restores the factory settings.

5.8ALARMS

The Alarms menu allows you to define alarm settings for Shallow Alarm, Depth Alarm and Temperature Upper/Lower/Rate.

Page 34

FF520

Page 32
Image 32
Standard Horizon Ff520 installation and operation guide Transducer Setup, Alarms