166
APPENDIX
4 DTR OUT 2) X-ON/X-OFF mode
Indicates whether or not the printer can receive data from the host.
This signal is a space, except in the following cases.
1. After reset until communication is possible
2. During test printing
6 DSR IN Signal line that indicates if the host computer can receive data.
SPACE: host can receive
MARK: host cannot receive
In the X-ON/X-OFF or Star mode, the status of this signal is not confirmed.
The status of this signal is not confirmed.
This signal can be specified as an internal reset signal using of DIP Switch 7 (page 163).
MARK of 1ms or longer activates the reset.
7 SG Signal ground
20 DTR OUT Same as RTS (Pin 4).
25 INIT IN This signal can be specified as an internal reset signal using of DIP Switch 8 (page 163).
SPACE of 1ms or longer activates the reset.
Pin
No. Signal
Name Direction Function
1
2
3
4
6
1
2
3
4
5
6
7
8
20
F-GND
TXD
RXD
RTS
DSR
20
25
7
S-GND
DTR
INIT
Printer side
(D-sub 25 pin) IBM PC side
3
2
7
8
6
5
1
4
F-GND
TXD
RXD
RTS
CTS
DSR
S-GND
DCD
DTR
9 pin25 pin