161
APPENDIX
4 DTR OUT
2) X-ON/X-OFF mode
Indicates whether or not the printer can receive data from the host.
This signal is a space, except in the following cases.
1. After reset until communication is possible
2. During test printing
5 SG Signal ground
6 DSR IN Signal line that indicates if the host computer can receive data.
SPACE: host can receive
MARK: host cannot receive
In the X-ON/X-OFF or Star mode, the status of this signal is not confirmed.
The status of this signal is not confirmed.
This signal can be specified as an internal reset signal using Switch 7 of DIP Switch 1
(page 156). MARK of 1ms or longer activates the reset.
7 RTS OUT Same as DTR (Pin 4).
8 INIT IN This signal can be specified as an internal reset signal using Switch 8 of DIP Switch 1
(page 156). SPACE of 1ms or longer activates the reset.
9 N/C Not connected
Pin
No. Signal
Name Direction Function
Printer Status Memory SW #4-4
10
1. From when the power is turned on or I/F
reset until communication possible BUSY BUSY
2. Test printing BUSY BUSY
3. Paper feed by paper feed switch BUSY
4. Stop due to no paper BUSY
5. During waiting for switch input in macro
execution — BUSY
6. Other errors BUSY
7. Receiving buffer full BUSY BUSY