| Lowest | Default | Highest |
|
Item | Value | Value | Value | Meaning |
|
|
|
|
|
AUTO STOP | OFF | OFF | ON | ON=Auto stop feature enabled. |
|
|
|
| OFF=Auto stop feature disabled. |
CSAFE | OFF | OFF | ON | ON=CSAFE communication enabled. |
|
|
|
| OFF=CSAFE communication disabled. |
LOCK OUT | OFF | OFF | ON | ON=Treadmill lock out enabled. |
|
|
|
| OFF=Treadmill lock out disabled. |
LOCKOUT ID | 10000 | 12345 | 65535 | Treadmill lockout ID. |
MINIMUM | 0.5/0.8 | 0.5/0.8 | 2.0/3.2 | Minimum speed in mph (UNITS=English), or km/hr (UNITS=Metric). |
SPEED* |
|
|
|
|
MAXIMUM | 5.0/5.0 | 10.0/16.0 | 12.5/20.0 | Maximum speed in mph (UNITS=English), or km/hr (UNITS=Metric). |
SPEED* |
|
|
| Caution: See Motor Calabration before making any changes. |
ACCELERA- | 25 | 25 | 60 | Time, in seconds, to reach maxmium speed from 0 mph (0 km/hr). |
TION TIME |
|
|
|
|
DECELERA- | 20 | 20 | 60 | Time, in seconds, to reach 0 mph (0 km/hr) from maximum speed. |
TION TIME |
|
|
|
|
|
|
|
|
|
*When the MINIMUM SPEED or MAXIMUM SPEED parameters are changed, the Treadmill will perform an auto calibration. To termi- nate the auto calibration and return the parameter to its default setting, press the STOP key.
MAINTENANCE MODE
Your Service Representative may need to check accumulated data about the past usage of your treadmill, test its motor and display con- trols, or investigate error messages. For these reasons, your treadmill is equipped with Maintenance Mode. Maintenance Mode includes all of the items available through Manager Mode, plus additional items for Service and Diagnostic use. To enter Maintenance Mode:
1.Press and hold the , , and keys together.
2.A beep will sound and “MAINTENANCE MODE” will display momentarily in the Information Window.
3. Release the remaining keys. “MCI VX.XX CKSM XXXX” will display in the Information Window.
The following keys are available in MAINTENANCE MODE:
Incline Keys: Displays the next and previous parameter, respectively. Keys will repeat if held.
Speed Keys: Adjust the value of the displayed parameter up and down, respectively, in increments of 1 unit or 0.01 unit, as appropriate for the parameter. These keys do not save the new value - see Start Key and Key below.
38 | STAR TRAC E SERIES TREADMILL OWNER’S MANUAL |