Lowest

Default

Highest

 

Item

Value

Value

Value

Meaning

 

 

 

 

 

DATE

1.00

1.98

12.99

Treadmill manufacture date.

STOP SWITCH

-

-

-

Either E-Stop or Lanyard.

LAST DECK

0

0

65,535

Number of miles (UNITS=English), or km (UNITS=Metric) since the running deck

 

 

 

 

was last serviced or replaced.

LAST BELT

0

0

65,535

Number of miles (UNITS=English) or km (UNITS=Metric) since the running belt

 

 

 

 

was last replaced.

PROGRAM

-

-

-

Provides access to programs usages and counters. (See Sub Menu)

STATS

 

 

 

 

LED TEST

-

-

-

LED Testing function, Press OK to begin

KEYPAD TEST

-

-

-

LED Testing function, Press OK to begin.

HEART RATE

-

-

-

HEART RATE Test function.

TEST

 

 

 

 

SERIAL PORTS

-

-

-

RS 232 Ports test (Manufacture Test Only).

TEST

 

 

 

 

ERROR STATS

-

-

-

Provides Access to Error List.

LAST ERROR

-

-

-

Last Error List Menu, Press OK to View

LIST

 

 

 

 

CALIBRATION

-

-

-

Provides Access to View Calibration Data.

VALUES

 

 

 

 

MOTOR

-

-

-

Motor Calibration Function, Press OK to begin.

CALIBRATION

 

 

 

 

ELEV

-

-

-

Elevation Calibration Function, Press OK to begin.

CALIBRATION

 

 

 

 

BURN IN

-

-

-

Burn In Mode Function (Manufacture Only).

MODE

 

 

 

 

 

 

 

 

 

*When the MINIMUM SPEED or MAXIMUM SPEED parameters are changed, the Treadmill will perform an auto calibration. To termi- nate the auto calibration and return the parameter to its default setting, press the STOP key.

MOTOR CALIBRATION

The Motor Calibration function allows for calibration of the treadmill's speed function. CAUTION: Changing Max Speed setting may expose users to increase risk. Any changes to the treadmills maximum speed settings should be clearly communicated to all users of the treadmill. To enter the Motor Calibration function:

1.While in the Maintenance Mode, press the key, or navigate to the Motor Calibration by the next or the previous parameter buttons .

2.While in the Motor Calibration, press the key to begin the calibration. The information window will display “PWM= XXXXXX SPEED=XX.X” where the X’s are data the that test will generate.

When the test is finished the information window will display one of the 2 messages “Passed Calibration” or “Failed Calibration”. If “Failed Calibration” is displayed run test again, if it continues, call for maintenance.

3.Press the STOP key to exit the Motor Calibration function.