Part Number Bulletin Number SC2-620.2 Effective 1/12/2010
GP Series Portable Chillers
We are committed to a continuing program of product improvement
ECN No Copyright 2010 All rights reserved
Unpacking and Inspection
Shipping Information
In the Event of Shipping Damage
If the Shipment is Not Complete
CHAPTER 1 SAFETY
Table of Contents
CHAPTER 3 INSTALLATION
Flow Switch
CHAPTER 6 TROUBLESHOOTING
CHAPTER 5 MAINTENANCE
CHAPTER 7 APPENDIX
1-1 How to Use This Manual
Chapter 1 Safety
Safety Symbols Used in this Manual
9 Wear SAFETY GLASSES and WORK GLOVES
1-2 Warnings and Precautions
9 Use care when LOADING, UNLOADING, RIGGING, or MOVING this equipment
SYSTEM. This must be performed by a qualified service technician only
2-1 Models Covered in This Manual
Chapter 2 Functional Description
2-2 General Description
Chilled Water Circuit
Mechanical Features
2-3 Standard Features
Other Mechanical Features
Electrical Features
Refrigeration Features
2-4 Safety Devices and Interlocks
Controller Features
Other Features
Low Pressure Cutout no switch but done through the transducer
2-5 Optional Features
Flow Switch
High Pressure Cutout
Mounting Features
Voltage
Figure 1 Optional Pump Amperages
Construction
Full Load Amps
3-1 Uncrating
Chapter 3 Installation
3-2 Electrical Connections
3-4 Bypass Valve Considerations
3-3 Process Water Connections
3-5 Galvanic Corrosion Considerations
3-6 Water Treatment Considerations
Water-Cooled Chiller Condensers
3-7 Condenser Considerations
Air-Cooled Chiller Condensers
Remote Air-Cooled Chiller Condensers
Note Piping should be type “L” or type “K” refrigerant grade copper tubing only. Proper sizing and installation has a significant effect on system performance, reliability, and safety
GP Series Portable Chillers
Chapter 3 Installation
17 of
Figure 3 Liquid Line Sizing
Figure 2 Equivalent Length in Feet for Valves and Fittings
Line Size
Angle
Total Equiv
10 TON CIRCUIT
Length Ft
20 TON CIRCUIT
Total Equiv
30 TON CIRCUIT
Length Ft
50 TON CIRCUIT
Chapter 3 Installation
Figure 4 Discharge Line Sizing
GP Series Portable Chillers
21 of
Figure 5 Refrigerant Charge Determination
3-8 Checking Motor Direction
Three-Phase Compressors
Water Pumps
Condenser Fan
Part Number
3-9 Water Reservoir
Description
From Figure 28, 25F equates to 10% by volume of glycol required
Figure 6 Ethylene Glycol and Propylene Glycol Curves
pump
Example 45F set point minus 20F = 25F
3-10 Automatic Water Make-Up Option
3-12 Finishing Setup Setting Up Passwords
3-11 Initial Start-Up
1. Press the button to access the menu screen
To set password protections
or the following screen for the Supervisor Password
Chapter 3 Installation
Chapter 3 Installation
6. Press to accept the Password and move to the next line
GP Series Portable Chillers
28 of
Chapter 4 Operation
4-1 Panel Buttons, Indicator Lights, and Switches
Microprocessor Controller
Figure 7 - Controller Display
Figure 8 - Main Status Screen
4-2 Initial Start-up
Figure 9 - Menu Screen
Figure 10 - Operator Setpoints Screen
4-3 Status Screens
Figure 11 - Main Status Screen
Chapter 4 Operation
GP Series Portable Chillers
32 of
4-4 Access Levels
Figure 12 - Menu Screen
Controller Setpoints
4-7 Optional Communications
4-6 Alarms
Figure 13 - Operator Setpoints Screen
Chapter 4 Operation
GP Series Portable Chillers
36 of
Chapter 4 Operation
GP Series Portable Chillers
37 of
5-2 Filter Cleaning
Chapter 5 Maintenance
5-1 Lubrication
5-3 Maintaining the Condenser
5-4 Maintaining the Evaporator
5-6 Preventative Maintenance Service
5-5 Evaporator Process Piping Y-Strainer
Chapter 6 Troubleshooting
GP Series Portable Chillers
Chapter 6 Troubleshooting
41 of
Chapter 7 Appendix
Warranty Returns
7-1 Returned Material Policy
Credit Returns
7-2 Technical Assistance
Service Department
Parts Department
Sales Department
Air-Cooled Portable Chillers
7-3 Specifications
G-PAC-20
G-PAC-30
Chapter 7 Appendix
GP Series Portable Chillers
45 of
G-PAC-40
Chapter 7 Appendix
GP Series Portable Chillers
46 of
GPAC-70
Chapter 7 Appendix
GP Series Portable Chillers
47 of
GPAC-105
Chapter 7 Appendix
GP Series Portable Chillers
48 of
GPAC-175
G-PWC-20
Water-Cooled Portable Chillers
G-PWC-30
Chapter 7 Appendix
GP Series Portable Chillers
50 of
G-PWC-40
Chapter 7 Appendix
GP Series Portable Chillers
51 of
GPWC-70
Chapter 7 Appendix
GP Series Portable Chillers
52 of
GPWC-105
Chapter 7 Appendix
GP Series Portable Chillers
53 of
GPWC-175
5-15 ALL 60 Hz
7-4 Pump Curves, Flow, and Pressure Considerations
60 Hertz Pump Curves
Head ft
Head ft
70-210 ALL 60 Hz
Capacity Gal/min
50 Hertz Pump Curves
5-15 ALL 50 Hz
ACS CHILLER PUMPS
Head m
ACS CHILLER PUMPS
20-50 ALL 50 Hz
Head m
Capacity liter/min
Pure Water at 40F
Calculating Chiller Nominal Flow and Pressure to Process
GP Series Portable Chillers
7-5 Remote Air-Cooled Chiller Configurations
Chapter 7 Appendix
59 of
7-6 Typical Ductwork for Air-Cooled Chillers
Chapter 7 Appendix
GP Series Portable Chillers
61 of
GP Series Portable Chillers
7-7 Piping Diagrams
Chapter 7 Appendix
62 of
Chapter 7 Appendix
GP Series Portable Chillers
63 of
Chapter 7 Appendix
GP Series Portable Chillers
64 of
Chapter 7 Appendix
GP Series Portable Chillers
65 of
Chapter 7 Appendix
GP Series Portable Chillers
66 of
Chapter 7 Appendix
GP Series Portable Chillers
67 of
Chapter 7 Appendix
GP Series Portable Chillers
68 of
Chapter 7 Appendix
GP Series Portable Chillers
69 of
Chapter 7 Appendix
GP Series Portable Chillers
70 of
Chapter 7 Appendix
GP Series Portable Chillers
71 of
Chapter 7 Appendix
GP Series Portable Chillers
72 of
Chapter 7 Appendix
GP Series Portable Chillers
73 of