Feed Calibration
Options Screen This screen allows you to perform the feeder
calibrations for each feeder (in weight per
second). This is useful when the feed calibration
is giving you an error message (most commonly
caused by overfilling the hopper during the
calibration). Select a feeder and then follow
instructions. An error is shown if the current
feeder calibration feed time was too short, the
feed time was too long, or if the hopper weight
exceeded 110% of the set batch weight. In the
case that the feeder exceeded 110% (maximum
hopper weight) due to a high rate hopper then the
“Batch % for Feeder Cal” setting might be set too
high. Consult Sterling if this problem arises. The
current feeder calibration values are also shown
on this page. It is not necessary to perform
feeder calibrations. The blender will
automatically learn these values during the
batch.
Mechanical This screen allows the user to change the number
Options Screen of hoppers, the predetermined gate cycle time,
and the mixer bump time for detecting high level.
The gate cycle time has been measured and set
at the factory, but might need to be adjusted if we
change the mechanical design of the gate,
solenoids, and air cylinders. This setting will vary
depending on whether you are using a gate.