INSTALLATION INSTRUCTIONS
COMMISSIONING
1.COMMISSIONING
•Close all openable doors and windows in the room
•Ignite the stove and operate on maximum for 10 minutes
•Remove the plastic sight plug from the right hand side of the stove
•Position a lighted smoke match just inside the draught diverter opening
•Check all smoke is drawn into the opening by looking through the sight hole, Diagram 1.
If there is any doubt, run the stove for a further 10 minutes, and repeat the test.
1
AR1493
If there are any extractor fans in adjacent rooms, the test must be repeated with the fans running on maximum and interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE
AND SEEK EXPERT ADVICE.
For future reference record the installation details on the commissioning sheet at the start of these instructions.
14