Stovax Huntingdon 30 Servicing Instructions, Replacing Parts, Ignition Lead And Piezo, Gas Valve

Models: Huntingdon 30

1 23
Download 23 pages 18.92 Kb
Page 18
Image 18
4.IGNITION LEAD AND PIEZO

SERVICING INSTRUCTIONS

REPLACING PARTS

The pilot unit can now be removed by undoing the two screws, Diagram 6

6

AR1445

3.2• Reassemble in reverse order

• Do not overtighten.

NOTE: TAKE CARE NOT TO DISCONNECTTHE SENSOR WIRES OF THE GAZCO FLUE SURE SYSTEM ON REPLACING THE THERMOCOUPLE

4.IGNITION LEAD AND PIEZO

4.1• Follow the above Pilot Unit instruction to access the back of the pilot assembly

Disconnect the ignition lead from the electrode

Remove the front cover from the control valve, Diagram 7 and 8

Disconnect the other end of the ignition lead from the valve body noting the route of the ignition lead

7

AR0915

8

AR0916

Replace with a new ignition lead following the same route as the old one

Replace the valve cover and the pilot assembly

4.2• Check operation of the new ignition lead.

5.PIEZO

5.1The piezo assembly used on this appliance is not serviceable and is unlikely to fail.

6.GAS VALVE

6.1• Turn the gas supply off at the isolation device, referring to Diagram 9

Disconnect the 2 x 8mm and 1 x 4mm gas pipe fittings at the back of the gas valve (A)

Disconnect the thermocouple, (B)

9

 

 

 

 

C

 

 

 

B

A

C

A

A

 

 

AR0943

Remove the front cover from the control valve, Diagram

10 and 11

10

AR0915

.

18

Page 18
Image 18
Stovax Huntingdon 30 manual Servicing Instructions, Replacing Parts, Ignition Lead And Piezo, Gas Valve