Stovax Huntingdon 30 Installation Instructions, Technical Specification, 8575MCUC - P8575MCUC

Models: Huntingdon 30

1 23
Download 23 pages 18.92 Kb
Page 8
Image 8
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

Covering the following models

8575MCUC - P8575MCUC

 

Model

Gas

Gas

 

Working

 

NOX

Aeration

Injector

Gas Rate

Input kW (Gross)

Country

 

 

 

 

 

 

 

 

 

 

m3/h

 

 

 

 

 

CAT.

 

Type

 

Pressure

 

Class

 

 

High

Low

 

 

Huntingdon 30

I2H

Natural Gas

 

20 mbar

 

5

1 x 7.5mm

260

0.435

4.6

2.5

 

GB, IE

 

8503CFMCUC

 

G20

 

 

 

 

 

 

 

Gross

Gross

 

 

Huntingdon 30

I3P

LPG Propane

 

37 mbar

 

5

1 x 13.5mm

110

0.170

4.4

2.3

 

GB, IE

 

P8503CFMCUC

 

G31

 

 

 

 

 

 

 

Gross

Gross

 

 

 

 

 

 

 

 

Efficiency Class II

 

 

 

 

 

 

 

 

 

 

 

 

Flue Outlet Size 127mm (5”) ø

 

 

 

 

 

 

 

 

 

 

 

Gas Inlet Connection Size 8mm ø

 

 

 

 

 

 

Minimum flue specification

T260 / N2 / O / D / 1

 

 

 

 

 

 

 

 

Maximum flue temperature

180°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing Checklist

Qty Description

1 Stove

1Flue infill plate

1Front coal

1Flame baffle

1Coal set

1Rear ceramic

1Fixing kit containing

1Instruction manual

8

Page 8
Image 8
Stovax Huntingdon 30 manual Installation Instructions, Technical Specification, Covering the following models