Stovax Huntingdon 30 Site Requirements, Installation Instructions, Flue And Chimney Requirements

Models: Huntingdon 30

1 23
Download 23 pages 18.92 Kb
Page 9
Image 9
SITE REQUIREMENTS

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

1.FLUE AND CHIMNEY REQUIREMENTS

1.1The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm in diameter. (5").

1.2The minimum flue height for the appliance must be 3 metres (10ft). Any horizontal flue run from the rear outlet must not exceed 100mm from the back of the appliance.

1.3The chimney or flue must be free from any obstruction. Any damper plates must be removed or secured in the fully open position, and no restrictor plates fitted.

1.4The chimney must be swept prior to the installation, but it need not be swept if it can be seen the chimney is clean and unobstructed throughout its entire length.

1.5A5" (127mm) liner must be used if fitting the stove into an existing brick built chimney.

Larger lined flues can work, but in some instances could cause cold start flue problems resulting in nuisance shutdown. Lined flues above 7" (175mm) are not recommended.

1.6Due to recent changes to European chimney standards, new flues and chimneys are described by their temperature, pressure and resistance to corrosion, condensation and fire. To assist in identifying the correct flue system, the minimum flue specification is shown in the Technical Specification. Existing chimneys are not covered by this system.

2.VENTILATION

2.1Consult the rules in force.

Note: This appliance does not normally require any additional ventilation when installed in G.B.

3.INSTALLATION OF THE GAS SUPPLY

3.1Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.

3.2Ensure the gas supply is capable of delivering the required amount of gas, and is in accordance with the rules in force.

3.3Soft copper tubing and soft soldered joints can be used but must not be closer than 50mm to the base of the tray.

3.4A means of isolating the gas supply to the appliance must be provided independent of any appliance control.

3.5All supply gas pipes must be purged of any debris that may have entered, prior to connection to the appliance.

4.APPLIANCE LOCATION

4.1This appliance must stand on a non-combustible hearth that is at least 12mm thick, and project a minimum of 50mm from the base of the stove in all directions, Diagram 1.

1

A = 653

B = 501

C = 12

AR0604

4.2This appliance must not be installed in a room that contains a bath or shower.

4.3The stove is not suitable for installation against a combustible wall; all combustible materials must be removed from the area behind the stove.

4.4Ensure you comply to all minimum clearances to combusible materials. See Diagram 2 & 2A.

2

150

225

150

 

 

853

AR0522

2A

AR0531

In a non-combustible recess be careful to allow enough clearance at the sides and rear of the stove to perform spillage tests and reach the controls.