9. Basic functions
Frequency
Reset
Run command
When H21 is 0 | When H21 is 1 |
9.4Accel/Decel time and unit setting
Accel/Decel time setting based on Max frequency
| Group |
|
| LED Display |
|
| Parameter Name |
|
| Set |
|
| Min/Max |
|
| Factory |
|
| Unit |
| |
|
|
|
|
|
|
| Value |
|
| Range |
|
| Defaults |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Drive |
|
| ACC |
|
| [Accel time] |
|
|
| - |
| 0/6000 |
| 5.0 |
|
| sec |
| ||
| group |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| dEC |
|
| [Decel time] |
|
|
| - |
| 0/6000 |
| 10.0 |
|
| sec |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Function |
|
| F21 |
|
| [Max frequency] |
| - |
| 0/400 |
| 60.0 |
|
| Hz |
| ||||
| group 1 |
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Function |
|
| H70 |
|
| [Frequency | Reference | for |
| 0 |
| 0/1 |
| 0 |
|
|
|
| ||
| group 2 |
|
|
|
| Accel/Decel] |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| H71 |
|
| [Accel/Decel | Time setting | - |
| 0/2 |
| 1 |
|
|
|
| ||||
|
|
|
|
|
| unit] |
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Set the desired Accel/Decel time at ACC/dEC in Drive group.
If H70 is set to 0 {Max frequency}, Accel/Decel time is the time that takes to reach the max freq from 0 Hz. Desired Accel/Decel time unit is settable at the H71.
Accel/Decel time is set based on F21 – [Max frequency]. For instance, if F21 is set to 60Hz, Accel/Decel time 5 sec, and run frequency 30Hz, time to reach 30Hz would be 2.5 sec.
Max. freq. |
|
60Hz |
|
Run Freq. |
|
30Hz |
|
Run |
|
command |
|
Accel time | Decel time |