11. Monitoring
11.Monitoring
11.1Operating status monitoring Output current
| Group |
|
| LED Display |
|
| Description |
|
| Set |
|
| Min/Max |
|
| Factory |
|
| Unit |
|
|
|
|
|
|
|
| value |
|
| range |
|
| default |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Drive group |
|
| CUr |
|
| Output current |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| Inverter output current can be monitored in Cur. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Motor RPM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Group |
|
| LED Display |
|
| Description |
|
| Set |
|
| Min/Max |
|
| Factory |
|
| Unit |
|
|
|
|
|
|
|
| value |
|
| range |
|
| default |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Drive group |
|
| rPM |
|
| [Motor RPM] |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Function |
|
| H31 |
|
| [Number of motor poles] |
| - |
| 2/12 |
| 4 |
|
|
|
| |||
| group 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| H40 |
|
| [Control mode select] |
| - |
| 0/2 |
| 0 |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| H74 |
|
| [Gain for Motor rpm display] |
| - |
| 1/1000 |
| 100 |
| % |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Motor rpm can be monitored in rPM.
When H40 is set to 0 {V/F control} or 1 {PID control}, the Inverter output frequency (f) is displayed in RPM using the formula below. Motor slip is not considered.
120 | ⋅ | f |
| H 74 | ||
RPM = |
|
|
| | ⋅ |
|
H | 31 |
| 100 | |||
|
| |
|
H31 : Enter the number of rated motor poles on the nameplate.
H74 : This parameter is used to change the motor speed display to rotating speed (r/min) or mechanical speed (m/mi).
Inverter DC Link Voltage
|
| Group |
|
| LED Display |
|
| Parameter Name |
|
| Set |
|
| Min/Max |
|
| Factory |
|
| Unit |
|
|
|
|
|
|
|
|
|
| value |
|
| range |
|
| default |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| Drive group |
|
| dCL |
|
| [Inverter DC Link Voltage] |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| Inverter DC link voltage can be monitored in dCL. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
| 2 times the value of input voltage is displayed while motor is at a stop. |
|
|
|
|
|
| |||||||||||
|
|
|
|
| It is the voltage detected between P1 and N terminal of power terminal. |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|