12. Protective functions

For example, set F59 to 3 to make stall prevention active during Acceleration and constant run.

When stall prevention is executed during acceleration or deceleration, Accel/Decel time may take longer than the user-setting time.

When stall prevention is activated during constant run, t1, t2 executed in accordance with the value set in ACC - [Accel time] and dEC - [Decel time].

Current

F60

Freq.

Multi-functi on output or relay

During acceleration

t1

t2

During constant run

DC voltage

Freq.

Multi-function output or relay

During deceleration