LG Electronics SV-iC5 Series manual Function list, Function group

Models: SV-iC5 Series

1 141
Download 141 pages 11.63 Kb
Page 45
Image 45
Function group 1

7. Function list

Function group 1

 

LED

 

 

Parameter

 

 

Min/Max

 

 

 

Description

 

 

Factory

 

 

Adjustable

 

 

Page

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

display

 

 

name

 

 

range

 

 

 

 

 

defaults

 

 

during run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 0

 

 

[Jump code]

 

0/60

 

This parameter sets the parameter code

 

1

 

 

O

 

5-5

 

 

 

 

 

 

 

 

 

 

number to jump.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 1

 

 

[Forward/

 

0/2

 

0

 

Fwd and rev run enable

 

0

 

 

X

 

9-8

 

 

 

 

 

Reverse run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Forward run disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disable]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Reverse run disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 2

 

 

[Accel pattern]

 

0/1

 

0

 

Linear

 

0

 

 

X

 

9-13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 3

 

 

[Decel pattern]

 

 

 

 

1

 

S-curve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 4

 

 

[Stop mode

 

0/2

 

0

 

Decelerate to stop

 

0

 

 

X

 

9-18

 

 

 

 

 

select]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Stop via DC brake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Free run to stop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 8

 

 

[DC Brake

 

 

0/60 [Hz]

 

 

 

This parameter sets DC brake start

 

5.0

 

 

X

 

10-1

 

 

1)

 

 

start

 

 

 

 

 

frequency.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency]

 

 

 

 

 

 

It cannot be set below F23 - [Start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency].

 

 

 

 

 

 

 

 

 

 

 

F 9

 

 

[DC Brake

 

 

0/60 [sec]

 

 

 

When DC brake frequency is reached, the

 

0.1

 

 

X

 

10-1

 

 

 

 

 

wait time]

 

 

 

 

 

inverter holds the output for the setting time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

before starting DC brake.

 

 

 

 

 

 

 

 

 

 

 

F10

 

 

[DC Brake

 

0/200

 

 

 

This parameter sets the amount of DC

 

50

 

 

X

 

10-1

 

 

 

 

 

voltage]

 

[%]

 

 

voltage applied to a motor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It is set in percent of H33 – [Motor rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current].

 

 

 

 

 

 

 

 

 

 

 

F11

 

 

[DC Brake

 

 

0/60 [sec]

 

 

 

This parameter sets the time taken to

 

1.0

 

 

X

 

10-1

 

 

 

 

 

time]

 

 

 

 

 

apply DC current to a motor while motor is at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a stop.

 

 

 

 

 

 

 

 

 

 

 

F12

 

 

[DC Brake

 

0/200

 

 

 

This parameter sets the amount of DC

 

50

 

 

X

 

10-2

 

 

 

 

 

start voltage]

 

[%]

 

 

voltage before a motor starts to run.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It is set in percent of H33 – [Motor rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F13

 

 

[DC Brake

 

 

0/60 [sec]

 

 

 

DC voltage is applied to the motor for DC

 

0

 

 

X

 

10-2

 

 

 

 

 

start time]

 

 

 

 

 

Brake start time before motor accelerates.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F14

 

 

[Time for

 

 

0/60 [sec]

 

 

 

This parameter applies the current to a

 

1.0

 

 

X

 

10-11

 

 

 

 

 

magnetizing a

 

 

 

 

 

motor for the set time before motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

motor]

 

 

 

 

 

accelerates during Sensorless vector control.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) : Set F4 to 1 (Stop via DC brake ) to view this function

7-3

SV-iC5

Page 45
Image 45
LG Electronics SV-iC5 Series manual Function list, Function group