12. Protective functions
12.7Frequency command loss
| Group |
|
| LED display |
|
| Parameter Name |
|
| Set |
|
| Min/Max |
|
| Factory |
|
| Unit |
| ||
|
|
|
|
|
|
| value |
|
| setting |
|
| default |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| I/O group |
|
| I16 |
|
| [Criteria for | analog | input |
| 0 |
| 0/2 |
| 0 |
|
|
|
| |||
|
|
|
|
|
| signal loss] |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| [Drive | mode | select | after |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| I62 |
|
| loss | of | frequency |
| - |
| 0/2 |
| 0 |
|
|
|
| |||
|
|
|
|
|
|
| command] |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| I63 |
|
| [Wait | time after loss of |
| - |
| 1/12 |
| 1.0 |
|
| Sec |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| frequency command] |
|
|
|
| 0/17 |
|
|
|
|
|
|
| |||
|
|
|
| I54 |
|
| output | 11 |
|
|
|
| 12 |
|
|
|
| |||||
|
|
|
|
|
| terminal select] |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
| I55 |
|
| 11 |
|
|
|
| 17 |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Select the Drive mode when frequency reference set via V1 and I or (V1+I) input terminal or communication
option is lost.
I16 : This is to set the criteria for analog input signal loss when frequency reference is given by V1, I, V1+I or Communication option.
I16 | [Criteria for analog | 0 | Disabled (Does not check the analog input signal loss) |
| input signal loss] |
|
|
| 1 | When less than the value set in I 2, I 7, I 12 is entered | |
|
|
|
|
|
| 2 | When below the value set in I 2, I 7, I 12 is entered |
|
|
|
|
EX 1) The inverter determines that the freq reference is lost when DRV- Frq is set to 3 (Analog V1 input), I 16 to 1 and analog input signal is less than half of the minimum value set in I 7.
EX 2) The inverter determines that the freq reference is lost when DRV- Frq is set to 6 (V1+I), I 16 to 2 and V1 input signal is either below the minimum value set in I 7 or I input value is less than the I 12 value.
I62 : When no frequency command is given for the time set in I63, set the drive mode as the table below.