0.01~600.00

9. Basic functions

More precise time unit can be set corresponding to load characteristics as shown below.

Code

Parameter Name

Setting range

Set

Description

 

 

value

 

 

 

 

 

 

 

 

 

H71

[Accel/Decel Time setting

0.01~600.00

0

Unit: 0.01 sec.

 

 

 

 

 

0.1~6000.0

1

Unit: 0.1 sec.

 

unit]

 

 

 

 

 

1~60000

2

Unit: 1 sec.

 

 

 

 

 

 

 

Accel/Decel time based on Run frequency

 

Group

 

 

LED display

 

 

Parameter name

 

 

Set

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

 

 

 

 

value

 

 

range

 

 

defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

 

 

ACC

 

 

[Accel time]

 

-

 

0/6000

 

5.0

 

 

sec

 

 

group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dEC

 

 

[Decel time]

 

-

 

0/6000

 

10.0

 

 

sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

 

H70

 

 

[Frequency reference

for

 

1

 

0/1

 

0

 

 

 

 

 

group 2

 

 

 

 

Accel/Decel]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accel/Decel time is set at the ACC/dEC.

If you set H70 to 1 {Delta frequency}, Accel/Decel time is the time that takes to reach a target freq from run freq (Currently operating freq.).

When H70 and Accel time are set to 1 {Delta frequency} and 5 sec, respectively,

(A zone: run freq 10 Hz applied first, B zone: Operating via 10 Hz, different run freq is not issued

C:30Hz Run freq (in this case, Target freq) issued while 10 Hz run freq is applied. But the preset accel time 5 sec is maintained. )

Freq.

 

 

30Hz

 

 

(Target freq.)

command

 

 

(Run freq.)

(Delta freq.)

10Hz

A

B

C

Time

5

7

12

[sec]

Run

 

 

 

command

 

 

 

5 sec

 

5 sec

 

9-11