LG Electronics SV-iC5 Series manual Function list, Drive Group, range, rotation

Models: SV-iC5 Series

1 141
Download 141 pages 11.63 Kb
Page 44
Image 44
range

7. Function list

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive Group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED

 

 

Parameter

 

Min/Max

 

 

 

Description

 

 

Factory

 

 

Adjustable

 

 

Page

 

 

display

 

 

name

 

 

range

 

 

 

 

 

defaults

 

 

during run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CUr

 

 

[Output

 

 

 

 

 

This parameter displays the output current to

 

-

 

-

 

11-1

 

 

 

 

 

current]

 

 

 

 

 

the motor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rPM

 

[Motor RPM]

 

 

 

This parameter displays the number of Motor

 

-

 

-

 

11-1

 

 

 

 

 

 

 

 

 

 

 

RPM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dCL

 

 

[Inverter

DC

 

 

 

This parameter displays DC link voltage inside

 

-

 

-

 

11-1

 

 

 

 

 

link voltage]

 

 

 

 

the inverter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vOL

 

[User

display

 

 

 

This parameter displays the item selected at

 

 

vOL

 

-

 

11-2

 

 

 

 

 

select]

 

 

 

 

 

H73- [Monitoring item select].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vOL

 

Output voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POr

 

Output power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tOr

 

Torque

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

nOn

 

 

[Fault Display]

 

 

 

This parameter displays the types of faults,

 

-

 

-

 

11-2

 

 

 

 

 

 

 

 

 

 

 

frequency and operating status at the time of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drC

 

 

[Direction

of

 

F/r

 

This parameter sets the direction of motor

 

 

F

 

 

O

 

9-7

 

 

 

 

 

motor

rotation

 

 

 

rotation when drv - [Drive mode] is set to either

 

 

 

 

 

 

 

 

 

 

 

 

 

 

select]

 

 

 

 

 

0 or 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

Forward

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r

 

Reverse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-2

SV-iC5

Page 44
Image 44
LG Electronics SV-iC5 Series Function list, Drive Group, range, This parameter displays DC link voltage inside, rotation