S U B - Z E RO MODELS 315I A N D 315IP I N S TA L L AT I O N

ELECTRICAL R E Q U I R E M E N T S

PLUMBING R E Q U I R E M E N T S

I M P O RTA N T N OT E

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your services.

A 115 V AC, 60 Hz, 15 amp circuit breaker and electrical supply are required. A separate circuit is required for each unit.

The Model 315I(P) is equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding-type electrical outlet.

Follow the National Electrical Code and local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Installation Specifications illustra- tions on pages 7–8.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Do not use an extension cord or two- prong adapter. Electrical ground is required on this appliance. Do not remove the power supply cord ground prong.

Shut off the power to the electrical outlet.

Rough in the water supply line. Connect a 1/4” OD copper line to the house supply. Be sure to use an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit. Do not use “self-piercing” valves. A saddle valve (part #4-20-088-0) is available from your Sub-Zero dealer. A line filter is required when the water supply has a high mineral content. The water supply must maintain 20 psi (1.4 bar) to 80 psi (5.5 bar) of water pressure.

The water supply and drain should be roughed in and ready at the point of installation. An electrical outlet directly behind the ice maker will make the installation easier. All electrical, water and drain connections must conform to local codes. For location of the water supply, refer to the Installation Specifications illustra- tions on pages 7–8.

IMPORTANT NOTE: Although the Model 315I(P) has been designed to be serviced in place, in some cases it may be necessary to pull the unit out for service. For that reason do not restrict access to the unit at the front, top and bottom.

If a floor is to be installed after the ice maker, shims the thickness of the floor should be installed under the Model 315I(P) to keep the ice maker level with the floor. Also, allow 1/8"

(3)clearance on each side of the unit for protruding screw heads.

Installations on a slab: Use a Model 315IP, with built-in drain pump and pump the water to the point of drainage. Drain pump models will pump one story high.

Installations over a crawl space or

basement: Either a gravity drain (Model 315I) or a drain pump (Model 315IP) unit may be used. If there is not enough room behind the ice maker for a drain/waste water receptacle, the drain will have to be below the floor.

IMPORTANT NOTE: All plumbing must meet local codes.

 

Dimensions in parentheses are in

6

millimeters unless otherwise specified.