S U B - Z E RO MODELS 315I A N D 315IP I N S TA L L AT I O N
MODEL 315I G R AV I T Y D R A I N
The drain and inlet water tubes must be plumbed before connecting to the ice maker. Refer to the illustrations below. All horizontal runs of drain lines must have a 1/4" (6) per 12"
(305)fall. An air gap will likely be required between the ice maker drain tube and the drain/waste water receptacle. A stand pipe with a trap below it can be used for the drain/waste water receptacle.
IMPORTANT NOTE: Poor drainage will cause a high rate of ice melting in the ice storage bin.
1)Place the ice maker in front of the installa- tion opening. Adjust leveling legs to the approximate height.
2)Remove the door (with hinges), control knob, control panel, access panel and lower face plate.
3)Route the water inlet line (1/4" OD copper tube) from the wall through the ice maker to the front.
4)Route the drain line from the wall position through the ice maker. If you have a hori- zontal run longer than 5' (1.5 m), the drain should be vented at the back of the unit.
5)If the electrical outlet for the ice maker is behind the unit, plug in the unit.
6)Position the unit in the installation opening.
7)Cut the water inlet line to the required length.
8)Flush the water line. Place the flare nut on the water line and flare the end of the copper tube.
Drain Tube |
Clamp |
Drain |
Stand Pipe |
Drain tube detail
9)Attach the flare nut to the male flare on the inlet water valve.
10)Cut the drain tube to the required length.
11)Connect the 5/8" drain tube to the storage bin drain fitting at the bottom of the bin. Secure with hose clamps. Be sure that the drain tube is pushed up well past the barbs on the drain fitting. If needed to ease instal- lation, soak the drain hose in hot water just before connecting to the fitting.
12)Turn on the water supply and check for leaks.
13)Replace the door (with hinges), control knob, control panel, access panel and lower face plate. Level the unit as needed.
I N S TA L L AT I O N S P E C I F I C AT I O N S
Model 315I
| 1/8"(3) |
WATER |
|
INLET | |
TUBE | VALVE |
DRAIN | WATER |
TUBE | FILTER |
24"
(610)LOCATE DRAIN WITHIN 2" DIA. AREA 23" BACK FROM FRONT OF UNIT
151/4"
(387) MIN.
TOP VIEW
| 341/2" |
| (876) NOMINAL |
| 333/4" |
| (857) MIN. |
| WATER |
WATER | FILTER |
| |
INLET TUBE | |
| VALVE |
DRAIN |
|
TUBE |
|
151/4"
(387) MIN.
FRONT VIEW