5-3-12 GROUNDING WIRE (2)
Disconnect the two grounding wires from the alternator and the inverter unit.
Tools : Screw driver
5-3-13 CONTROL BOX and INVERTER UNIT
Removing the cover bracket from the bottom of the inverter unit, separate the control box and inverter unit. For further taking apart, refer to "INVERTER UNIT
COMPONENTS" and "CONTROL BOX COMPONENTS".
INVERTER UNIT COMPONENTS
Inverter unit
Bracket (Cover)
4.0- 6.0 N・m
40 - 60 kgf・cm
(3.0 - 4.4 ft・lbs)
Wire harness
Screw and Washer
M6 Bolt
Note : Remove the nut for the grounding wire on the back side before loosening the bolt.
– 28 –