5-3-12 GROUNDING WIRE (2)

Disconnect the two grounding wires from the alternator and the inverter unit.

Tools : Screw driver

5-3-13 CONTROL BOX and INVERTER UNIT

Removing the cover bracket from the bottom of the inverter unit, separate the control box and inverter unit. For further taking apart, refer to "INVERTER UNIT

COMPONENTS" and "CONTROL BOX COMPONENTS".

INVERTER UNIT COMPONENTS

Inverter unit

Bracket (Cover)

4.0- 6.0 Nm

40 - 60 kgfcm

(3.0 - 4.4 ftlbs)

Wire harness

Screw and Washer

M6 Bolt

Note : Remove the nut for the grounding wire on the back side before loosening the bolt.

– 28 –

Page 31
Image 31
Subaru Robin Power Products RG3200IS, RG4300I, RG2800I Control BOX and Inverter Unit, Components and Control BOX Components