(3) Remove the fuel strainer.

[ For electric start models ]

(4)Remove the battery cover and disconnect battery cables.

(5)Remove the battery from frame.

5-3-4 GROUNDING WIRE

Remove the grounding wire at the right bottom side of

control panel.

M6 Nut : 1pce.

5-3-5 CHOKE WIRE

Loosen the screw that fixes the choke wire to carburetor choke lever.

Turn the engine switch to “CHOKE” position to disconnect the choke wire from the choke lever.

Tools : Screw driver

5-3-6 CONTROL PANEL and INVERTER UNIT

(1)Loosen the four screws and remove the upper front cover.

M6 x 18mm Screw : 4pcs.

(2)Loosen the two bolts and remove the lower front cover.

M6 x 18mm Flange bolt : 2pcs.

Tools : Screw driver

Fuel

strainer

Battery

cables

Choke wire

– 24 –

Page 27
Image 27
Subaru Robin Power Products RG2800I For electric start models, Grounding Wire, Choke Wire, Control Panel and Inverter Unit