4-2) AC OUTPUT MEASURING

SWITCH

A

~

TO AC RECEPTACLE

F

V

 

 

~

LOAD

Use a circuit above for measuring AC output. A hot plate or lamp with a power factor of 1.0 may be used as a load. Adjust the load and rpm, and check that the voltage range is as specified in the following table at the rated amperage and rated rpm.

Model

 

Specification

 

 

 

 

 

120V / 60Hz

220V / 50Hz

230V / 50Hz

240V / 60Hz

 

 

 

 

 

 

RG2800i

 

 

 

 

RG3200i

 

 

 

 

RG4300i

117-130

215-238

225-248

235-259

RG2800iS

 

 

 

 

RG3200iS

 

 

 

 

RG4300iS

 

 

 

 

 

 

 

 

 

Voltage range

4-3) DC OUTPUT MEASURING

SW Load

To DC Terminal

Measurement of DC output is executed with the switch turned ON while the current is regulated at 8.3A by adjusting the load to the generator. If the voltage is within the range from 6V to 14V, the voltage output is normal.

NOTE : If a battery is connected as a load to the generator, the DC output voltage will increase by approximately 1 to 2 V.

Therefore, carefully observe the electrolyte level and do not overcharge the battery.

– 17 –

Page 20
Image 20
Subaru Robin Power Products RG3200IS, RG2800IS, RG4300IS service manual AC Output Measuring, DC Output Measuring