(1) ENGINE SWITCH | RG2800i / RG3200i / RG2800iS | |||
The engine switch is designed for easy operation with the interlocking | STOP | ENGINE SWITCH | ||
mechanism between the fuel cock and the choke furnished. |
| RUN | ||
| To start the engine, turn the knob to the position. |
| CHOKE | |
| (Choke valve is closed.) |
| ||
CHOKE |
|
| ||
|
|
| ||
| Keep the knob in this position after the engine | RG4300i / RG3200iS / RG4300iS | ||
| starts. (The engine can be started with the knob at | |||
| (With electric starter) | |||
RUN | this position when the engine is warm.) | |||
| ENGINE SWITCH | |||
|
|
| ||
| To stop the engine, return the knob to the position. |
| STOP | |
|
| RUN | ||
STOP | (The fuel cock is closed as well.) |
|
| |
|
| START | ||
|
|
|
(2) KEY SWITCH for electric starting models.
To start the engine with electric starter.
(3) MULTI MONITOR | LED display | Operation hour lamp | |||
■ LED display |
|
|
|
| Voltage lamp |
Operation hour, voltage and frequency are |
| MULTI MONITOR | Hours | ||
indicated in turns by means of depressing the LED |
|
|
| ||
|
|
| V | Frequency | |
display changeover switch. In addition, "O_Lod" |
|
|
| ||
|
|
| Hz | lamp | |
(overload) will be indicated when the generator is |
|
|
| ||
|
|
|
|
| |
in the overload condition or appliance(s) is out of |
| AUTO |
|
|
|
order. | Engine oil level |
|
|
| |
|
| ||||
In this case, stop the engine immediately and check | warning lamp |
|
|
|
|
|
|
|
|
| |
the appliance and/or generator for overloading. |
|
|
|
|
|
After the check and remedy, restarting the engine |
|
| LED display | ||
will resume displaying in the normal manner. | saving lamp |
| saving switch |
| changeover switch |
■Operation hour lamp
Lamp (red) is turned on when LED display is changed over into operation hour indication.
■Voltage lamp
Lamp (red) is turned on when LED display is changed over into voltage indication.
■Frequency lamp
Lamp (red) is turned on when LED display is changed over into frequency indication.
■LED display changeover switch
When depressing this switch, indication in LED display is changed over in turns;
operation hour → voltage → frequency → operation hour.
When starting the engine, operation hour is indicated in LED display at first.
■
When depressing this switch,
■
Lamp (green) is turned on while
■Engine oil level warning lamp
When the engine oil level is lower than the specified level, the lamp is turned on. Then engine will be stopped.
– 8 –