(1) ENGINE SWITCH

RG2800i / RG3200i / RG2800iS

The engine switch is designed for easy operation with the interlocking

STOP

ENGINE SWITCH

mechanism between the fuel cock and the choke furnished.

 

RUN

 

To start the engine, turn the knob to the position.

 

CHOKE

 

(Choke valve is closed.)

 

CHOKE

 

 

 

 

 

 

Keep the knob in this position after the engine

RG4300i / RG3200iS / RG4300iS

 

starts. (The engine can be started with the knob at

 

(With electric starter)

RUN

this position when the engine is warm.)

 

ENGINE SWITCH

 

 

 

 

To stop the engine, return the knob to the position.

 

STOP

 

 

RUN

STOP

(The fuel cock is closed as well.)

 

 

 

 

START

 

 

 

(2) KEY SWITCH for electric starting models.

To start the engine with electric starter.

(3) MULTI MONITOR

LED display

Operation hour lamp

LED display

 

 

 

 

Voltage lamp

Operation hour, voltage and frequency are

 

MULTI MONITOR

Hours

indicated in turns by means of depressing the LED

 

 

 

 

 

 

V

Frequency

display changeover switch. In addition, "O_Lod"

 

 

 

 

 

 

Hz

lamp

(overload) will be indicated when the generator is

 

 

 

 

 

 

 

 

in the overload condition or appliance(s) is out of

 

AUTO

 

 

 

order.

Engine oil level

 

 

 

P-SAVE

 

 

In this case, stop the engine immediately and check

warning lamp

 

 

 

 

 

 

 

 

 

the appliance and/or generator for overloading.

 

 

 

 

 

After the check and remedy, restarting the engine

Auto-power

 

Auto-power

 

LED display

will resume displaying in the normal manner.

saving lamp

 

saving switch

 

changeover switch

Operation hour lamp

Lamp (red) is turned on when LED display is changed over into operation hour indication.

Voltage lamp

Lamp (red) is turned on when LED display is changed over into voltage indication.

Frequency lamp

Lamp (red) is turned on when LED display is changed over into frequency indication.

LED display changeover switch

When depressing this switch, indication in LED display is changed over in turns;

operation hour voltage frequency operation hour.

When starting the engine, operation hour is indicated in LED display at first.

Auto-power saving switch

When depressing this switch, auto-power saving function is activated.

Auto-power saving lamp

Lamp (green) is turned on while auto-power saving function is activated.

Engine oil level warning lamp

When the engine oil level is lower than the specified level, the lamp is turned on. Then engine will be stopped.

– 8 –

Page 11
Image 11
Subaru Robin Power Products RG4300IS, RG3200IS, RG2800IS service manual Engine Switch, Multi Monitor