Subaru Robin Power Products RGX240D manual Models RGX180 and RGX240 have a pushbutton circuit

Models: RGX240 RGX240D RGX180

1 65
Download 65 pages 50.78 Kb
Page 18
Image 18
Models RGX180 and RGX240 have a pushbutton circuit

5-2-6 CIRCUIT BREAKERS

 

 

Models RGX180 and RGX240 have a pushbutton circuit

 

breaker

and Model RGX240D two

pushbutton circuit

1

breakers. Nomrallp, the pushbutton circuit breaker is closed

 

with the

button pushed into the panel to keep the circuit

:

live. If an overcurrent runs. the button comes out to break

 

the circuit. The circuit can be closed again by simply push-

 

ing the button in. The circuit breaker

is a thermo-sensitive

i

type so. if the temperature inside the circuit breaker is still

 

high immediately after the circuit has opened, the button

 

may not be able to be pushed in to the ON position. or ma>-

1

come back out again at once. In that case,wait a while until

 

the inside temperature falls. and then push the button in.

Fig. 5-8

 

Circuit breaker capacities are as follows:

 

1

 

 

 

Circuit Breaker

Quantity

Model

 

 

Specification

 

 

Capacity

 

per Unit

 

 

 

 

 

 

RGX180

 

11ov.

120v

 

15A

1

RGX180

,

22OV,

23OV.

240V

8A

I

1

RGX240

 

1 lOV,

120v

 

20A

1

 

 

 

RGX240

 

220V.

230V.

240V

10A

 

1

RGX240D

 

11 Ol22OV. 12Ol24OV

10A

 

2

 

 

 

 

Table

5-3

 

 

- 16 -