Subaru Robin Power Products RGX240D, RGX180 manual 12oui24ou, Refer to, er. See Fig, ohms

Models: RGX240 RGX240D RGX180

1 65
Download 65 pages 50.78 Kb
Page 37
Image 37
12oui24ou

l 50Hz

11 OVi22OV.

12OVf24OV

 

 

 

 

 

 

 

 

I

 

 

 

Wire color

 

RED

,

BLACK

“,“:y

- $1

 

 

I

 

 

I

 

 

 

 

 

 

 

 

WHITE

1.15Q

 

1.15x?

!

 

l 60Hz

1lou;22ou.

 

12oui24ou

 

 

 

 

9-l-2

MEASURING

INSULATION

RESISTANCE

ROTOR

Refer to 8-4

MEASURING

INSULATION

RESISTANCE.

 

9-2

ROTOR

ASSEMBLY

 

 

 

 

9-2-l

WI-NDING

RESISTANCE

MEASURING

 

Check the resistance between the two slip rings with a test-

er. (See Fig. 9-2.)

The resistance is normal if it is an>vhere from 6 ohms to

13 ohms.

TESTER

9-2-2 MEASURING INSULATION RESISTANCE

Refer to 8-4 MEASURING INSULATION RESISTANCE.

9-2-3 CLEANING SLIP RINGS

The slip ring surfaces must be uniformly bright. Slip :-ings showing black spots. excessive wear, or uneven wear must be repaired. A stained slip ring lowers generator effi;rency and output voltage. Polish the slip rings with fine sandpaper while turning the rotor until rough spots disappear. Care should be taken not to touch the rotor ~011swith the sand- paper. (See Fig. 9 -3 .)

Fig. 9-2

ROTOR

f=-%

SLIP RING

-\

....

\

Fig. 9-3

-35-

Page 37
Image 37