reads normal or pilot lamp lightens.

9-6 RECEPTACLE and AC PLUG

Check the current-carrying parts of the receptacles and AC plugs and their leads and plastic parts for burns.

9-7 VOLTMETERS and PILOT LAMP

Apply AC voltage to a terminal and check if the voltmeter

reads normal or pilot lamp lightens.

AC

VOLTMETER

9-8 DIODE STACK ASSEMBLY

--

I-

Fig. 9-9

Fig. 9- 70

Fig. 9- 7 1

The internal circuitry of the diode stack assembly is as shown in Fig. 9 -10. Check inter-terminal continuity with a tester as shown in Fig. 9 - 11 to see that the results are as shown in Table 9 - 2.

TERMINAL’CURRENT: TERMINAL

NOTE:

1-j

+A --+--- 6 Current flows from A (+-I to B (-1.

C e D Current does not flow from C (+I to D l-1.

- Check both terminals.