5-3-4 DUAL VOLTAGE TYPE (RGX240D)
The dual voltage
Each of MC1 and MC2 generates an AC 12OV (or 1lOV) with the same phase, which is one half the rated output voltage. This model has two receptacles to output one half of the rated voltage from each of the receptacles (112OVor 1lOV,.
MC1 and MC2 are connected in series to each other so that the rated voltage (21OV or 21OVj can be obtained from the receptacles. (See Fig. 5 - 19.)
5-4 CHANGE of ENGINE PARTS
I
Fig. 5- 78
240 (22O)V
Fig. 5- 19
For details of the engine. please refer to the EYZO service manual. The RGS Series ?mplgs engine parts specia! to the RGX to suit the modified engine. The engine parts can be classified b>- ignition system. control system. fuel system. and cooling system. The engine parts fur each of these systems are explained belox.
5-4-l IGNITION SYSTEM
RGX Series employs a solid state ignition system (T.I.C.). Pleasercfcr to the section on Robin Solid State Ignition Engine in the EYl5. EYlO Service Manual.
All models use a primary exciting coil of especial performance and lead length.
NOTE: Be careful not to use an excitingcoil of different performance because itcan damage the automatic voltage regulator.
- 22 -