4 — OPERATOR SERVICE
| ERROR MESSAGE | DEFINITION OF ERROR |
|
|
|
056 | SHORTED CIRCUIT | Excessive load detected in right front outrigger |
| RF OUTRIGGER | circuit on |
057 | OPEN CIRCUIT | A load of less than 70mA detected in left rear |
| LR OUTRIGGER | outrigger circuit on |
058 | SHORTED CIRCUIT | Excessive load detected in left rear outrigger |
| LR OUTRIGGER | circuit on |
059 | OPEN CIRCUIT | A load of less than 70mA detected in right rear |
| RR OUTRIGGER | outrigger circuit on |
060 | SHORTED CIRCUIT | Excessive load detected in right rear outrigger |
| RR OUTRIGGER | circuit on |
069 | OPEN CIRCUIT | A load of less than 70mA detected in proportional |
| PROPORTIONAL | valve circuit on |
070 | SHORTED CIRCUIT | Excessive load detected in proportional valve |
| PROPORTIONAL | circuit on |
COMMENTS
Check for faulty solenoid coil/wiring at outrigger.
Check for faulty solenoid coil/wiring at outrigger.
Check for faulty solenoid coil/wiring at outrigger.
Check for faulty solenoid coil/wiring at outrigger.
Check for faulty solenoid coil/wiring at outrigger.
Check for faulty solenoid coil/wiring at proportional valve.
Check for faulty solenoid coil/wiring at proportional valve.