4 — OPERATOR SERVICE

 

ERROR MESSAGE

DEFINITION OF ERROR

 

 

 

056

SHORTED CIRCUIT

Excessive load detected in right front outrigger

 

RF OUTRIGGER

circuit on power-up.

057

OPEN CIRCUIT

A load of less than 70mA detected in left rear

 

LR OUTRIGGER

outrigger circuit on power-up.

058

SHORTED CIRCUIT

Excessive load detected in left rear outrigger

 

LR OUTRIGGER

circuit on power-up.

059

OPEN CIRCUIT

A load of less than 70mA detected in right rear

 

RR OUTRIGGER

outrigger circuit on power-up.

060

SHORTED CIRCUIT

Excessive load detected in right rear outrigger

 

RR OUTRIGGER

circuit on power-up.

069

OPEN CIRCUIT

A load of less than 70mA detected in proportional

 

PROPORTIONAL

valve circuit on power-up.

070

SHORTED CIRCUIT

Excessive load detected in proportional valve

 

PROPORTIONAL

circuit on power-up.

COMMENTS

Check for faulty solenoid coil/wiring at outrigger.

Check for faulty solenoid coil/wiring at outrigger.

Check for faulty solenoid coil/wiring at outrigger.

Check for faulty solenoid coil/wiring at outrigger.

Check for faulty solenoid coil/wiring at outrigger.

Check for faulty solenoid coil/wiring at proportional valve.

Check for faulty solenoid coil/wiring at proportional valve.