BIL-JAX 3522A
| ERROR MESSAGE | DEFINITION OF ERROR | COMMENTS |
|
|
|
|
031 | OPEN CIRCUIT JIB DOWN | A load of less than 70mA detected when jib down | Check for faulty jib down solenoid |
|
| circuit was energized | coil and wiring. |
032 | SHORTED CIRCUIT JIB | Excessive load detected when jib down circuit | Check for faulty jib down solenoid |
| DOWN | was energized. | coil and wiring. |
033 | OPEN CIRCUIT EXTEND | A load of less than 70mA detected in extend | Check for faulty boom extend |
|
| circuit on | solenoid coil/wiring. |
034 | SHORTED CIRCUIT EXTEND | Excessive load detected in extend circuit on | Check for faulty boom extend |
|
| solenoid coil/wiring. | |
035 | OPEN CIRCUIT RETRACT | A load of less than 70mA detected in retract | Check for faulty boom retract |
|
| circuit on | solenoid coil/wiring. |
036 | SHORTED CIRCUIT | Excessive load detected in retract circuit on | Check for faulty boom retract |
| RETRACT | solenoid coil/wiring. | |
037 | OPEN CIRCUIT PLATFORM | A load of less than 70mA detected in platform | Check for faulty level up solenoid |
| LEVEL UP | level up circuit on | coil/wiring. |
038 | SHORTED CIRCUIT | Excessive load detected in platform level up | Check for faulty level up solenoid |
| PLATFORM LEVEL UP | circuit on | coil/wiring. |
039 | OPEN CIRCUIT PLATFORM | A load of less than 70mA detected in platform | Check for faulty level down |
| LEVEL DOWN | level down circuit on | solenoid coil/wiring. |
040 | SHORTED CIRCUIT | Excessive load detected in platform level down | Check for faulty level down |
| PLATFORM LEVEL DOWN | circuit on | solenoid coil/wiring. |
041 | OPEN CIRCUIT PLATFORM | A load of less than 70mA detected in platform | Check for faulty boom rotate |
| CW | CW circuit on | solenoid coil/wiring. |
042 | SHORTED CIRCUIT | Excessive load detected in platform CW circuit | Check for faulty boom rotate |
| PLATFORM CW | on | solenoid coil/wiring. |
043 | OPEN CIRCUIT PLATFORM | A load of less than 70mA detected in platform | Check for faulty boom rotate |
| CCW | CCW circuit on | solenoid coil/wiring. |
044 | SHORTED CIRCUIT | Excessive load detected in platform CCW circuit | Check for faulty boom rotate |
| PLATFORM CCW | on | solenoid coil/wiring. |
045 | OPEN CIRCUIT TURNTABLE | A load of less than 70mA detected in rotate CW | Check for faulty rotate CW |
| CW | circuit on | solenoid coil/wiring. |
046 | SHORTED CIRCUIT | Excessive load detected in rotate CW circuit on | Check for faulty rotate CW |
| TURNTABLE CW | solenoid coil/wiring. | |
047 | OPEN CIRCUIT TURNTABLE | A load of less than 70mA detected in rotate CCW | Check for faulty rotate CCW |
| CCW | circuit on | solenoid coil/wiring. |
048 | SHORTED CIRCUIT | Excessive load detected in rotate CCW circuit on | Check for faulty rotate CCW |
| TURNTABLE CCW | solenoid coil/wiring. | |
049 | OPEN CIRCUIT OUTRIGGER | A load of less than 70mA detected in outrigger | Check for faulty outrigger retract |
| RETRACT | retract circuit on | solenoid coil/wiring. |
050 | SHORTED CIRCUIT | Excessive load was detected when Outrigger | Check for faulty outrigger retract |
| OUTRIGGER RETRACT | Retract circuit was energized. | solenoid coil/wiring. |
051 | OPEN CIRCUIT OUTRIGGER | A load of less than 70mA detected in outrigger | Check for faulty outrigger extend |
| EXTEND | retract circuit on | solenoid coil/wiring. |
052 | SHORTED CIRCUIT | Excessive load was detected in outrigger extend | Check for faulty outrigger extend |
| OUTRIGGER EXTEND | circuit on | solenoid coil/wiring. |
053 | OPEN CIRCUIT | A load of less than 70mA detected in left front | Check for faulty solenoid |
| LF OUTRIGGER | outrigger circuit on | coil/wiring at outrigger. |
054 | SHORTED CIRCUIT | Excessive load was detected in left front | Check for faulty solenoid |
| LF OUTRIGGER | outrigger circuit on | coil/wiring at outrigger. |
055 | OPEN CIRCUIT | A load of less than 70mA detected in right front | Check for faulty solenoid |
| RF OUTRIGGER | outrigger circuit on | coil/wiring at outrigger. |