Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B Temperature Display, Error Codes, Buzzer

Models: JWE-2400CUA-R-25B JWE-24000CUA-L-25B

1 79
Download 79 pages 58.49 Kb
Page 26
Image 26

8. Temperature Display

Indicates the average water temperature read by the wash tank or booster tank thermistor. Indicates water temperature selected by the water temperature lamps beside the display. The factory default setting is to indicate wash water temperature and rinse water temperature alternately every 5 seconds. To adjust the display change cycle time, or to fix the temperature display for either wash or rinse water temperature and indicate the other temperature while the "CHANGE" button is pressed, see service menu items 09, 12 and 14 in "II.F.7.b) Service Menu Chart."

The temperature display range is 32°F to 199°F (0°C to 99°C). To change the display scale, see "Temperature Display Scale" (service menu item 13) in "II.F.7.b) Service Menu Chart."

The temperature display updates every 5 seconds for the wash tank and the booster tank.

9. Error Codes

In the event of operation outside of normal parameters, the control board identifies the issue with an error code and beeps. If more than one error occurs, the display cycles through the relevant error codes. For service corrections, see "III.B. Error Codes."

 

Error Codes

A1

Wash Tank Auto Fill Error

A2

Booster Tank Auto Fill Error

A3

Wash Tank Water Level Error

o1

Booster Tank Water Level Error 1

(Booster Tank Water Level Float Switch Closed)

 

o2

Booster Tank Water Level Error 2

(Booster Tank Water Level Float Switch Open)

 

H1

Wash Tank Thermistor Error (short)

H2

Wash Tank Thermistor Error (open)

H3

Booster Tank Thermistor Error (short)

H4

Booster Tank Thermistor Error (open)

H5

ROM/RAM Error

H6

EEPROM Error

L1

Conveyor Overload or Table Limit Error 1

L2

Conveyor Overload or Table Limit Error 2

b1

Booster Tank Error

b2

Booster Tank Water Level Safety Error

10. Buzzer

At the end of an auto fill cycle or other mode operation, the buzzer turns on for 0.1 second and off for 0.1 second 10 times.

In case of an error, the buzzer turns on for 0.1 second and off for 0.9 second repeatedly until the error is reset. To turn off the beep, press the down button.

When a button is pressed, the buzzer turns on for 0.1 second.

To adjust the buzzer volume, use the volume control on the control board.

21

Page 26
Image 26
Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B service manual Temperature Display, Error Codes, Buzzer