Hoshizaki JWE-24000CUA-L-25B Disconnect the rinse pump motor wiring at the closed end connectors

Models: JWE-2400CUA-R-25B JWE-24000CUA-L-25B

1 79
Download 79 pages 58.49 Kb
Page 58
Image 58
6)Disconnect the rinse pump motor wiring at the closed end connectors.

6)Disconnect the rinse pump motor wiring at the closed end connectors.

7)Remove the nut from the flexible tube at the rinse pump motor discharge outlet and the bolts securing the bracket to the unit base.

8)Remove the band from the pipe joint of the booster tank discharge pipe behind the rinse pump motor and the flexible tube at the rinse pump motor suction inlet. Pull the end of flexible tube out of the booster tank discharge pipe.

Note: Use a hand mirror for easy removal.

9)Remove the rinse pump motor together with the bracket. Remove the band from the pipe joint of the rinse pump motor suction inlet pipe and flexible tube to release the

flexible tube.

10)Unscrew the bracket, and remove the rinse pump motor.

11)To replace, reverse the above procedure. Note:

1.Be careful not to mix up the wire colors. Miswiring will cause reversal of the pump motor, resulting in improper operation.

2.Cover the connections with the original plastic sheet cover and secure with a nylon tie. Make sure the connections are situated so that water and condensation cannot reach the connections.

3.Be sure to use new O-rings and gaskets. Be careful of the direction of the U-packing for the suction inlet pipe.

12) Make a trial run, and check for water leaks.

 

Rinse Pump Motor

[JWE-2400CUA-L-25B]

 

 

* For JWE-2400CUA-R-25B, fan motor and rinse

 

 

pump motor are located behind control box

Sunction Inlet Pipe

U-Packing

 

 

 

Discharge

Outlet Nut

Flexible Tube

Booster Tank

Drain Hose

Rinse Pump Motor

Fan Motor

53

Page 58
Image 58
Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B Disconnect the rinse pump motor wiring at the closed end connectors