k) Conveyor Overload or Table Limit Error 2 (L2)

k) Conveyor Overload or Table Limit Error 2 (L2)

If the unit shuts down with "L1" in the display and restarts in 3 seconds after the cause of the overload is removed, and the inverter sends another overload signal within 3 seconds after the conveyor moves, the unit completely shuts down, "L2" appears in the display, and the buzzer sounds.

To reset, use the "ON/OFF" button to turn the unit off and then back on.

If the unit shuts down with a conveyor overload error, the error signal from the inverter is reset, and the unit restarts after 3 seconds. If the cause of the overload (e.g. dish caught in conveyor) has not been removed by then, the unit starts and stops repeatedly. To prevent this repetition, if the same error occurs within 3 seconds, the unit remains shut down.

If the unit shuts down with the table limit switch closed, the unit restarts after one or more racks are removed, and the table limit switch does not normally close again within 3 seconds.

See the chart below for possible causes and remedies.



Code

L 2

Error

Inverter sends another conveyor overload signal or table limit switch closes again within 3 seconds after “L1” error resets and unit restarts.

Operation

Unit stops.

Item

Conveyor

Gear Motor

Inverter

Table Limit Switch

Possible Cause

Jammed.

Defective (not moving smoothly).

Defective.

Defective.

Improper operation.

Remedy

Remove obstacle.

Repair.

Repair or replace.

Repair or replace.

Instruct operator.

Defective.

Repair or replace.