Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B service manual Error Code Log

Models: JWE-2400CUA-R-25B JWE-24000CUA-L-25B

1 79
Download 79 pages 58.49 Kb
Page 32
Image 32

Error

Problem

Operation

Reset

Code

 

Booster Tank Thermistor Error (open)

Normal

After replacing failed component,

H4

 

(Booster tank

alarm resets.

Thermistor senses abnormal temperature

heaters off)

 

 

 

 

(at or below -6°F (-21°C)).

 

 

H5

ROM/RAM Error

Whole unit

After replacing control board, alarm

Control board ROM/RAM fails.

stops

resets.

 

 

 

 

EEPROM Error

Whole unit

After replacing control board, alarm

H6

EEPROM fails.

stops

resets.

 

 

 

 

Conveyor Overload or Table Limit Error 1

Unit stops

After error signal stops, alarm resets.

L1

Inverter sends conveyor overload signal or

 

 

 

 

 

 

table limit switch closes.

 

 

 

Conveyor Overload or Table Limit Error 2

Whole unit

Use "ON/OFF" button to turn the unit

L2

After unit stops with "L1" error and restarts,

stops

off and then back on.

 

 

 

another error signal is sent within 3

 

 

 

seconds.

 

 

b1

Booster Tank Error

Normal

After booster tank error is resolved,

Booster tank error output contacts open.

 

alarm resets.

 

 

 

 

Booster Tank Water Level Safety Error

Whole unit

Use "ON/OFF" button to turn the unit

b2

Booster tank water level safety float switch

stops

off and then back on.

 

 

 

opens after booster tank water level float

 

 

 

switch closes.

 

 

2. Error Code Log

Use the "ON/OFF" button to turn off the unit. Press and hold the "CHANGE" button, then press the "ON/OFF" button. "01" should appear on the display. Use the down arrow button to scroll to service menu items 21 through 25. 21 is the most recent error. Press the "CHANGE" button to view the selected service menu item. Press the "CHANGE" button once again to return to the main service menu list. If no errors exist in the log, "--" is displayed.

Press the "ON/OFF" button to exit the service menu. The display goes blank.

To erase the log, press and hold the up and down buttons for 3 seconds with one of the error codes displayed. The unit beeps once and the entire log clears.