Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B Inadequate Rinse, Too low, Call electrician

Models: JWE-2400CUA-R-25B JWE-24000CUA-L-25B

1 79
Download 79 pages 58.49 Kb
Page 50
Image 50
3. Inadequate Rinse

3. Inadequate Rinse

Inadequate rinse

Problem

Low Rinse Pump

Output

Rinse Spray Arms

Dish Rack

Rinse (Booster Tank)

Water

Rinse Cycle Time

Voltage

Possible Cause

Clogged with foreign matter.

Rinse water line scaled.

Voltage drop.

Rinse pump defective.

Clogged.

Out of position.

Low pump output.

Improperly loaded.

Temperature too low.

Too short.

Too low.

Remedy

Clean.

Clean.

Remove cause.

Replace.

Clean.

Set in position.

See “Low Rinse Pump Output.”

Load correctly.

Raise setting or see Heater Not Energized.

Adjust longer.

Call electrician.

45

Page 50
Image 50
Hoshizaki JWE-24000CUA-L-25B Inadequate Rinse, Inadequate rinse Problem Low Rinse Pump Output Rinse Spray Arms, Too low