Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B service manual Chart, E. Timing, Auto Fill, Cycle

Models: JWE-2400CUA-R-25B JWE-24000CUA-L-25B

1 79
Download 79 pages 58.49 Kb
Page 18
Image 18
1. Auto Fill

13

Booster TankE. Timing

"ON/OFF" Button

ON

 

OFF

"AUTO FILL" Lamp

ON

 

OFF

"READY" Lamp

ON

 

OFF

"WASH" Lamp

ON

 

OFF

Service Panel Switch

CLOSED

 

OPEN

Rinse Pump

ON

 

OFF

Water Valve

ON

 

OFF

Water Level Float Switch

CLOSED

 

OPEN

Backup Water Level

CLOSED

Float Switch

OPEN

Water Level Safety Float

CLOSED

Switch

OPEN

Booster Tank Thermistor

Setpoint

Booster Tank Heater

ON

 

OFF

Water Level Sensor

CLOSED

 

OPEN

Buzzer

ON

 

OFF

Wash Tank Heater

ON

 

OFF

Service menu item 03

Auto Fill Cycle Rinse Time (*13 min) 2 gal (7.8L)/min x 13 min = 20 gal (101L)

Note 1

Note 1

(Repeat)

Note 3

Approx. 13 gal (50L) water level

Note 2

* Factory default, adjustable by service menu

1. Auto Fill

E. Timing

Cycle

Chart

Note 1: Booster tank auto fill delay time (*10 seconds): If auto fill cycle starts immediately after the booster tank water level float switch opens, the booster tank fills up too soon, and the water valve energizes/de-energizes frequently, resulting in no hot water supply.

Note 2: After the rinse pump motor de-energizes, there is a 5-second dwell time to stabilize the water level before checking the water level sensor status.

Note 3: If the booster tank water level float switch does not close after 10 minutes in booster tank auto fill, error code "A2" (booster tank auto fill error) appears in the display, and the unit shuts down.

Page 18
Image 18