Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B j Conveyor Overload or Table Limit Error 1 L1

Models: JWE-2400CUA-R-25B JWE-24000CUA-L-25B

1 79
Download 79 pages 58.49 Kb
Page 42
Image 42
j) Conveyor Overload or Table Limit Error 1 (L1)

j) Conveyor Overload or Table Limit Error 1 (L1)

If the inverter sends an overload signal or the table limit switch closes, the unit shuts down, "L1" appears in the display, and the buzzer sounds.

After removing the jammed rack or the cause of the overload (the table limit switch opens or the inverter stops sending the overload signal), the alarm resets after 3 seconds, and the unit is ready to resume operation.

If the wash start switch is closed when the alarm resets, the upper spray arm wash pump starts first, followed by the lower spray arm wash pump, then the conveyor moves.

If the rinse start switch is closed when the alarm resets, the rinse pump starts, then the conveyor moves.

The heaters stay energized while the unit is off with "L1."

See the chart below for possible causes and remedies.



Code

L 1

Error

Inverter sends conveyor overload signal or table limit switch closes.

Operation

Unit stops.

Item

Conveyor

Gear Motor

Inverter

Table Limit Switch

Possible Cause

Jammed.

Defective (not moving smoothly).

Defective.

Defective.

Clean dishtable filled with racks.

Stays closed with reed switch defective or magnet off.

Remedy

Remove obstacle.

Repair.

Repair or replace.

Repair or replace.

Remove racks.

Repair or replace.

37

Page 42
Image 42
Hoshizaki JWE-24000CUA-L-25B, JWE-2400CUA-R-25B service manual j Conveyor Overload or Table Limit Error 1 L1