To Verify the Attached Storage

If online storage is connected to the HBA installed in a SPARC system, use the apply show-childrencommand to list the attached storage.

In the example that follows, a storage JBOD has twelve targets attached to one port of the dual-ported HBA.

TABLE 3-4

{0} ok apply

show-children

/pci@7c0/pci@0/pci@9/SUNW,emlxs@0

Device

ALPA

b6

WWPN 215000c0ff00223d

 

LUN

0

ESI Device

SUN

StorEdge 3510F D1046

Link attention

 

 

 

 

 

Device

ALPA

b9

WWPN 2100000c50c30555

 

LUN

0

Disk

SEAGATE ST3146807FC

0006

Device

ALPA

ba

WWPN 2100000c50c30525

 

LUN

0

Disk

SEAGATE ST3146807FC

0006

Device

ALPA

bc

WWPN 500000e010172831

 

LUN

0

Disk

FUJITSU MAP3147F SUN146G0301

Device

ALPA

c3

WWPN 2100000c50c3051b

 

LUN

0

Disk

SEAGATE ST3146807FC

0006

Device

ALPA

c5

WWPN 2100000c50c30567

 

LUN

0

Disk

SEAGATE ST3146807FC

0006

Device

ALPA

c6

WWPN 500000e0101727d1

 

LUN

0

Disk

FUJITSU MAP3147F SUN146G0301

Device

ALPA

c7

WWPN 21000004cf64f1db

 

LUN

0

Disk

SEAGATE ST336752FSUN36G 0508

Device

ALPA

c9

WWPN 2100000c50c30513

 

LUN

0

Disk

SEAGATE ST3146807FC

0006

Device

ALPA

ca

WWPN 500000e0101727b1

 

LUN

0

Disk

FUJITSU MAP3147F SUN146G0301

Device

ALPA

cb

WWPN 2100000c50c3050e

 

LUN

0

Disk

SEAGATE ST3146807FC

0006

Device

ALPA

cc

WWPN 21000004cf64dc04

 

LUN

0

Disk

SEAGATE ST336752FSUN36G 0508

Device

ALPA

cd

WWPN 21000004cf5728c0

 

LUN

0

Disk

SEAGATE ST373307FSUN72G 0407

{0} ok

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note – You may need to use the reset-allcommand before entering apply

show-children.

Chapter 3 Hardware Installation 21

Page 35