■CR 6381138. Sun StorEdge 3511 and 3510 Arrays can experience a SCSI transport failure for a’timeout’ reason.

Workaround: None at this time. A fix is being investigated.

■CR 6352189. OBP probe gives unexpected output for unmapped channel / Sun StorEdge 3500 family arrays. This only occurs on the first probe-SCSI-all after a reset.

Workaround: Perform another probe-scsi-all after a reset. The second try will yield correct results.

A fix will be made available in the next FCode release after version 1.50a8.

■CR 6306640. Enabling the BIOS of the “LP10000” card causes the system to fail to boot. Enabling the HBA BIOS hangs up all boot processes.

Workaround: None at this time. A fix is currently under investigation.

Disable the single or dual port HBA BIOS (default setting) and boot from the system disk, or other supported boot device.

Chapter 2 Supported System Configurations 11

Page 25
Image 25
Sun Microsystems PCI-X manual Supported System Configurations