Sun Microsystems V490 manual Code Example 6-10prtdiag Overtemperature Indication Output

Models: V490

1 274
Download 274 pages 18.59 Kb
Page 124
Image 124

In addition to that information, prtdiag with the verbose option (-v) also reports on front panel status, disk status, fan status, power supplies, hardware revisions, and system temperatures.

System Temperatures (Celsius):

-------------------------------

Device Temperature Status

---------------------------------------

CPU0

59

OK

CPU2

64

OK

DBP0

22

OK

CODE EXAMPLE 6-9 prtdiag Verbose Output

In the event of an overtemperature condition, prtdiag reports an error in the Status column.

System Temperatures (Celsius):

-------------------------------

 

Device

Temperature

Status

---------------------------------------

CPU0

62

OK

CPU1

102

ERROR

CODE EXAMPLE 6-10prtdiag Overtemperature Indication Output

Similarly, if there is a failure of a particular component, prtdiag reports a fault in the appropriate Status column.

Fan Status:

-----------

Bank

RPM

Status

--------- ------

CPU0

4166

[NO_FAULT]

CPU1

0000

[FAULT]

CODE EXAMPLE 6-11prtdiag Fault Indication Output

prtfru Command

The Sun Fire V490 system maintains a hierarchical list of all field-replaceable units (FRUs) in the system, as well as specific information about various FRUs.

96 Sun Fire V490 Server Administration Guide • August 2004

Page 124
Image 124
Sun Microsystems V490 manual Code Example 6-10prtdiag Overtemperature Indication Output