Sun Microsystems V490 manual About the Hssdc FC-AL Port, About the FC-AL Host Adapters

Models: V490

1 274
Download 274 pages 18.59 Kb
Page 72
Image 72

About the HSSDC FC-AL Port

The Sun Fire V490 system back panel includes an FC-AL port with a high-speed serial data connector (HSSDC).

Note – At this time, no Sun storage products are supported utilizing the HSSDC connector.

About the FC-AL Host Adapters

The Sun Fire V490 server uses an intelligent Fibre Channel processor as its on-board FC-AL controller. Integrated into the system centerplane, the processor resides on PCI Bus C and supports a 64-bit, 66-MHz PCI interface. The on-board FC-AL controller controls FC-AL operations on Loop A.

To take advantage of the dual-loop capability of the FC-AL backplane, an optional PCI FC-AL host adapter card and optional cable are required to control the second loop (Loop B). For this purpose, Sun offers the Sun StorEdge PCI Dual Fibre Channel Host Adapter card. See the Sun Fire V490 Server Parts Installation and Removal Guide, which is included on the Sun Fire V490 Documentation CD, for installation instructions.

Configuration Rules

The Sun Fire V490 server does not support all FC-AL host adapter cards. Contact your Sun sales or support engineer for a list of supported cards.

For best performance, install 66-MHz FC-AL host adapter cards into a 66-MHz PCI slot (slot 0 or 1, if available). See “About the PCI Cards and Buses” on page 31.

Note – Do not attempt to access any internal components unless you are a qualified service technician. Detailed service instructions can be found in the Sun Fire V490 Server Parts Installation and Removal Guide, which is included on the Sun Fire V490 Documentation CD.

44 Sun Fire V490 Server Administration Guide • August 2004

Page 72
Image 72
Sun Microsystems V490 manual About the Hssdc FC-AL Port, About the FC-AL Host Adapters