Sunlife Enterprises DM180, DM300, DM240 FRONT VIEW DIMENSIONS 15, 20 & 25 TON, Front, View

Models: DM300 DM240 DM180

1 56
Download 56 pages 41.42 Kb
Page 23
Image 23
FRONT
COIL GUARD
48-5/8"(15 TON)
52-5/8" (20, 25 TON)
CONDENSER COILS
(A)
CONTROL WIRING ENTRY
(B)
POWER WIRING ENTRY
COMPRESSOR ACCESS

356214-XIM-A-0108

BLOWER

 

ACCESS

FIELD-SUPPLIED

BLOWER MOTOR

DISCONNECT SWITCH

ACCESS

LOCATION

BLOWER

 

COMPARTMENT

 

ACCESS

 

(Auxiliary)

 

DOT PLUG

 

(For pressure

 

Drop Reading)

 

ELECTRIC/

 

GAS HEAT

 

ACCESS

 

ECONOMIZER / MOTORIZED DAMPER, FIXED OUTDOOR INTAKE AIR AND POWER EXHAUST RAIN HOODS (See detail "Y")

VENT AIR

OUTLET

HOODS

COMBUSTION

 

TON)

 

 

AIR INLET

 

TON)

-1/4"(15

25

 

 

 

(20,

21"

5"

7-1/8"VIEW

HOOD

125

-1/4”

 

136

6-3/8"

)

9-3/4"

(C)

GAS SUPPLY ENTRY

5-7/8"UTILITIES ENTRY DATA

46-5/8"

CONTROL BOX

ACCESS 35"

92"

11-1/2"

FRONT

VIEW

 

 

TON)

RETURN

 

 

25

 

-1/4"(15

TON)

 

 

12

(20,

AIR

 

-1/4”

 

 

33"

 

35

 

 

SUPPLY

AIR

2-3/4"FIGURE 13 - FRONT VIEW DIMENSIONS (15, 20 & 25 TON)21-1/2"

 

 

11-1/8"

UNIT BASE WITH RAILS

 

 

Shown separately to illustrate

(D)

Bottom Duct openings, Power

GAS SUPPLY

and Gas Piping Connection

ENTRY

locations

 

NOTE:

46-5/8"

For curb mounted units, refer to the curb hanger

9-1/4"

dimensions of the curb for the proper size of the

12-1/2"

supply and return air duct connections.

 

BOTTOM SUPPLY AND RETURN AIR OPENINGS (See Note)

3-3/4"

All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.

(B)

POWER WIRING ENTRY

(A)

8-1/8"CONTROL WIRING ENTRY

Manual background9-3/4"

UTILITIES ENTRY DATA

HOLE

OPENING SIZE (DIA.)

USED FOR

 

A

29 / 1-1/8” KO

Control Wiring

 

Side

19 / 3/4” NPS (Fem.)

 

Bottom

 

 

 

 

 

 

 

 

B

92 / 3-5/8” KO

Power Wiring

 

Side

 

 

 

76 / 3” NPS (Fem.)

 

Bottom

 

 

 

 

 

 

 

C

60 / 2-3/8” KO

Gas Piping

(Front)1

D

43 / 1-11/16” Hole

Gas Piping (Bottom)2

1.One-inch gas piping NPT required.

2.Opening in the bottom of the unit can be located by the slice in the insulation.

NOTE: All entry holes should be field sealed to prevent rain water entry into the building.

FIGURE 13 - FRONT VIEW DIMENSIONS (15, 20 & 25 TON)

Johnson Controls Unitary Products

23

Page 23
Image 23
Sunlife Enterprises DM180, DM300, DM240 FRONT VIEW DIMENSIONS 15, 20 & 25 TON, Front, View, Utilities Entry Data