Manuals
/
SUPER MICRO Computer
/
Computer Equipment
/
Network Card
SUPER MICRO Computer
5015M-UR, 5015M-NTR user manual Preface
Models:
5015M-U
5015M-UR
5015M-NT
5015M-NTR
1
5
134
134
Download
134 pages
15.96 Kb
1
2
3
4
5
6
7
8
<
>
Install
1. Intel 3010 Chipset System Block Diagram
Connecting Cables
Reset Button
Advanced Serverboard Setup
Unlock 2. Press release knob 3. Remove bezel assembly
Default Setting
Latency Timer
Jumper Settings
Ambient Operating Temperature
Page 5
Image 5
Preface
Notes
v
Page 4
Page 6
Page 5
Image 5
Page 4
Page 6
Contents
SUPER
1.0d
SUPERSERVER 5015M-UR
SUPERSERVER 5015M-NTR SUPERSERVER 5015M-NT
Printed in the United States of America
Manual Revision 1.0d Release Date April 15
Preface
Chapter 2 Server Installation
About This Manual
Manual Organization
Chapter 5 Advanced Serverboard Setup
Chapter 4 System Safety
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Preface
Chapter 2 Server Installation
Table of Contents
Preface
Chapter 1 Introduction
Chapter 5 Advanced Serverboard Setup
Chapter 4 System Safety
Chapter 7 BIOS
Chapter 6 Advanced Chassis Setup
Security
Appendices
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
1-1 Overview
Chapter Introduction
Processors
1-2 Serverboard Features
Memory
UIO 5015M-UR
Other Features
1-3 Server Chassis Features
System Power
Onboard Controllers/Ports
Front Control Panel
PCI Expansion Slots
I/O Backplane
Cooling System
ADDR
Figure 1-1. Intel 3010 Chipset System Block Diagram
CTRL
DATA
Headquarters
1-4 Contacting Supermicro
Europe
Asia-Pacific
2-3 Preparing for Setup
Chapter Server Installation
2-1 Overview
2-2 Unpacking the System
Choosing a Setup Location
Warnings and Precautions
Rack Precautions
Server Precautions
Rack Mounting Considerations
Ambient Operating Temperature
Reduced Airflow
Mechanical Loading
Installing the Inner Rails
2-4 Installing the System into a Rack
Identifying the Sections of the Rack Rails
Figure 2-1. Identifying the Sections of the Rack Rails
Locking Tabs
Installing the Outer Rails
Figure 2-2. Installing the Rack Rails
Figure 2-3. Installing the Server into a Rack
Installing the Server into the Rack
Figure 2-4. Installing the Server into a Telco Rack
Installing the Server into a Telco Rack
1. Accessing the inside of the system see Figure
2-5 Checking the Serverboard Setup
4. Installing add-on cards
2. Check the CPUs processors
Figure 2-5. Accessing the Inside of the System
Chapter 2 Server Installation
1. Accessing the drive bays
2-6 Checking the Drive Bay Setup
5. Supplying power to the system
2. DVD-ROM and floppy disk drives
3-2 Control Panel Buttons
Chapter System Interface
3-1 Overview
Figure 3-1. Universal Information LED States
3-3 Control Panel LEDs
3-4 SATA Drive Carrier LEDs
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
4-1 Electrical Safety Precautions
Chapter System Safety
4-2 General Safety Precautions
4-3 ESD Precautions
Figure 4-1. Installing the Onboard Battery
4-4 Operating Precautions
Precautions
Chapter Advanced Serverboard Setup
5-1 Handling the Serverboard
Unpacking
Installing the Processor
5-2 Processor and Heatsink Installation
Gold dot Socket key CPU key Notched corner CPU pin Load lever
CPU installed in socket PnP cap released from load plate
Removing the Heatsink
Installing the Heatsink
Connecting Power Cables
5-3 Connecting Cables
Connecting Data Cables
Figure 5-1. Front Control Panel Header Pins JF1
Connecting the Control Panel
DIMM Installation
5-5 Installing Memory
5-4 I/O Ports
Figure 5-2. Rear Panel I/O Ports
Memory Support
Figure 5-3. Installing DIMM into Slot
2. PCI card installation
5-6 Adding PCI Cards
1. PCI Expansion Slots
PCI Slot/Card Configurations
Figure 5-4. SUPER PDSMU Layout
5-7 Serverboard Details
UPER
PDSMU
Connector
Default Setting
PDSMU Quick Reference
Jumper
ATX Power Connector
5-8 Connector Definitions
Processor Power Connector
Power LED
NIC1 LED
HDD LED
NIC2 LED
Universal Information LED
Reset Button
Power Fail LED
Power Button
Universal Serial Bus USB0/1
Serial Ports
Universal Serial Bus Headers
Fan Headers
Universal Serial Bus Headers Pin Definitions USB2/3, USB4/5
Chassis Intrusion
Speaker Connector
ATX PS/2 Keyboard and PS/2 Mouse Ports
Wake-On-LAN
Power Supply Fail
Power SMB I2C Connector
Alarm Reset JAR
Wake-On-Ring
Power LED
LAN1/2 Ethernet Ports
Power LED Pin Definitions JLED
Pin# Defi nition 1 +5V 2 Key 3 Ground
VGA Enable/Disable
5-9 Jumper Settings
Explanation of Jumpers
CMOS Clear
Watch Dog Enable/Disable
LAN Enable/Disable
Power Force On Enable/ Disable
LAN Enable/Disable Jumper Settings JPL1, JPL2
PWR-LED
5-10 Onboard Indicators
LAN1/LAN2 LEDs
5-11 Floppy, IDE and SATA Drive Connections
Floppy Connector
SATA Ports
IDE Connector
IDE Drive Connector Pin Definitions IDE#1
SATA Port Pin Definitions SATA0 ~ SATA3
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
6-1 Static-Sensitive Devices
Chapter Advanced Chassis Setup
Tools Required
Precautions
Figure 6-1. Chassis Front and Rear Views
6-2 Control Panel
System Fan Failure
6-3 System Fans
Replacing System Fans
2. Installing a new fan
Figure 6-2. System Cooling Fans
6-4 Drive Bay Installation/Removal
Removing the Front Bezel
Figure 6-3. Removing the Front Bezel
Accessing the Drive Bays
1. Unlock 2. Press release knob 3. Remove bezel assembly
Figure 6-4. Mounting a SATA Drive in a Carrier
SATA Drive Installation
1. Mounting a SATA drive in a drive carrier
Figure 6-5. Removing a SATA Drive from the Server
2. Installing/removing hot-swap SATA drives
DVD-ROM and Floppy Drive Installation
Power Supply Failure
6-5 Power Supply
Removing/Replacing the Power Supply
5015M-UR/5015M-NTR
Power Supply Failure
5015M-U/5015M-NT
Removing/Replacing the Power Supply
1. Removing the power supply
Figure 6-6. Removing/Replacing the Power Supply
Chapter 6 Advanced Chassis Setup
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
System BIOS
Chapter BIOS
How To Change the Configuration Data
Starting the Setup Utility
7-3 Main BIOS Setup
7-2 Running Setup
Default settings are in bold text unless otherwise noted
Press the Delete key to enter Setup
BIOS Date
Main BIOS Setup Menu Main Setup Features
System Time
System Date
SATA Controller Mode
Native Mode Operation
Serial ATA SATA RAID Enable
ICH RAID Code Base Available when SATA RAID is Enabled
Transfer Mode
LBA Mode Control
Ultra DMA Mode
Type
Boot Features
7-4 Advanced Setup
QuickBoot Mode
QuietBoot Mode
Memory Cache Cache System BIOS Area
Power Loss Control
Cache Video BIOS Area
Resume On Modem Ring
Cache Base 512K-640K
Reset Configuration Data
Cache Extended Memory
Discrete MTRR Allocation
Latency Timer
Enable Master
Large Disk Access Mode
Clock Spectrum Feature
Legacy USB Support
USB Function
Advanced Processor Options
CPU Speed
No Execute Mode Memory Protection Available when supported by the
Intel R Virtualization Technology Available when supported by the CPU
Set Maximum Extended CPUID=3
I/O Device Configuration
Base I/O Address
Serial Port A
Interrupt
Serial Port B
Event Log Validity
DMI Event Logging
Event Log Capacity
View DMI Event Log
COM Port Address
Console Redirection
BAUD Rate
Console Type
Hardware Monitor Logic
CPU Temperature Threshold
Voltage Monitoring
CPU Temperature/CPU Second Core Temperature System Temperature
User Password Is
Supervisor Password Is
Set Supervisor Password
Set User Password
Boot Priority Order/Excluded from Boot Orders
7-6 Boot
Password on Boot
7-7 Exit
Load Setup Defaults
Exit Saving Changes
Exit Discarding Changes
Keyboard error
Appendix A BIOS POST Messages
Keyboard locked - Unlock key switch
Monitor type does not match CMOS - Run SETUP
System timer error
System CMOS checksum bad - Default configuration used
Real time clock error
Check date and time settings
Fail-Safe Timer NMI Failed
System cache error - Cache disabled
Allocation Error for device
Entering SETUP
Invalid System Configuration Data
PS/2 Mouse Boot Summary Screen
I/O device IRQ conflict
nnnn kB Extended RAM Passed
Press F2 to enter Setup
Press F1 to resume, F2 to Setup, F3 for previous
System BIOS shadowed
Video BIOS shadowed
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Recoverable POST Errors
Appendix B BIOS POST Codes
Terminal POST Errors
POST Code
Description
8254 timer initialization
POST Code
Test RAM between 512 and 640 kB
POST Code
Description
Check for SMART Drive optional
POST Code
Description
POST Code
The following are for boot block in Flash ROM
Description
POST Code
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
C-1 Introduction to Serial ATA and Parallel ATA
Intel HostRAID
Important Notes to the User
Serial ATA SATA
Intel Matrix Storage
Configuring BIOS settings for SATA RAID Functions Native Mode
RAID Configurations
Using the Intel ICH7R SATA RAID Utility Program
Creating a RAID 0 Volume
Creating a RAID 1 Volume
Creating a RAID 10 RAID 1+ RAID
Creating a RAID 5 Set Parity
Deleting a RAID Volume
Exiting the Intel Matrix Storage Manager Utility
Resetting to Non-RAID and Resetting a RAID HDD
New Operating System-Windows XP/2000/2003 Installation
C-2 Installing Windows XP/2000/2003 for RAID Systems
D-1 Introduction to the Intel ICH7R I/O Controller Hub
Appendix D Adaptec HostRAID Setup Guidelines
When Appropriate
Raid Level
Configuring the Adaptec SATA RAID
Adaptec Embedded SATA with HostRAID Controller Driver
Using the Adaptec RAID Configuration Utility ARC
Using the Array Configuration Utility ACU
Managing Arrays
To configure a disk drive
Configuring Disk Drives
Page
5. Read the warning message as shown in the screen below
Appendix D Adaptec HostRAID Setup Guidelines
To create an array
Creating Arrays
To assign properties to the new array
Assigning Array Properties
D-10
D-11
Adding a Bootable Array
Deleting a Bootable Array
Adding/Deleting Hotspares
D-12
Viewing Array Properties
D-13
To Rebuild an array
Rebuilding Arrays
D-14
RAID 1 only-the following prompt is also displayed
D-15
Deleting Arrays
D-16
Using the Disk Utilities
To access the disk utilities
To format a disk
D-17
To verify disk media
D-18
To Exit the Adaptec RAID Configuration Utility
D-19
D-20
D-2 Installing the Adaptec ICH7R Driver and the OS
Appendix E System Specifications
BIOS
Chipset
Memory Capacity
Power Supply
Weight
Serverboard
Chassis
Regulatory Compliance
Operating Environment
SUPERSERVER 5015M-UR/5015M-NT Users Manual