Chapter 6: Advanced Chassis Setup
6-5 Power Supply
5015M-UR/5015M-NTR
The SuperServer
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption. The Universal Information LED on the control panel will blink red slowly and remain so until the failed module has been replaced. Replacement modules can be ordered directly from Supermicro (see contact information in the Preface). The power supply mod- ules have a
Removing/Replacing the Power Supply
You do not need to shut down the system to replace a power supply module. The redundant feature will keep the system up and running while you replace the failed
1. Removing the power supply
First unplug the power cord from the failed power supply module. To remove the failed power module, push the release tab (on the back of the power supply) to the side and then pull the module straight out (see Figure
2. Installing a new power supply
Replace the failed power module with another