1. Intel 3010 Chipset System Block Diagram
Connecting Cables
Reset Button
Advanced Serverboard Setup
Unlock 2. Press release knob 3. Remove bezel assembly
Default Setting
Latency Timer
Jumper Settings
Ambient Operating Temperature
Page 100
Image 100
S
UPER
S
ERVER
5015M-UR/5015M-U/5015M-NTR/5015M-NT
User's Manual
Notes
B-6
Page 99
Page 101
Page 100
Image 100
Page 99
Page 101
Contents
1.0d
SUPER
SUPERSERVER 5015M-UR
SUPERSERVER 5015M-NTR SUPERSERVER 5015M-NT
Manual Revision 1.0d Release Date April 15
Printed in the United States of America
Chapter 2 Server Installation
Preface
About This Manual
Manual Organization
Chapter 4 System Safety
Chapter 5 Advanced Serverboard Setup
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Preface
Table of Contents
Chapter 2 Server Installation
Preface
Chapter 1 Introduction
Chapter 4 System Safety
Chapter 5 Advanced Serverboard Setup
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Appendices
Security
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Chapter Introduction
1-1 Overview
1-2 Serverboard Features
Processors
Memory
UIO 5015M-UR
1-3 Server Chassis Features
Other Features
System Power
Onboard Controllers/Ports
PCI Expansion Slots
Front Control Panel
I/O Backplane
Cooling System
Figure 1-1. Intel 3010 Chipset System Block Diagram
ADDR
CTRL
DATA
1-4 Contacting Supermicro
Headquarters
Europe
Asia-Pacific
Chapter Server Installation
2-3 Preparing for Setup
2-1 Overview
2-2 Unpacking the System
Warnings and Precautions
Choosing a Setup Location
Rack Precautions
Server Precautions
Ambient Operating Temperature
Rack Mounting Considerations
Reduced Airflow
Mechanical Loading
2-4 Installing the System into a Rack
Installing the Inner Rails
Identifying the Sections of the Rack Rails
Figure 2-1. Identifying the Sections of the Rack Rails
Figure 2-2. Installing the Rack Rails
Installing the Outer Rails
Locking Tabs
Installing the Server into the Rack
Figure 2-3. Installing the Server into a Rack
Installing the Server into a Telco Rack
Figure 2-4. Installing the Server into a Telco Rack
2-5 Checking the Serverboard Setup
1. Accessing the inside of the system see Figure
4. Installing add-on cards
2. Check the CPUs processors
Chapter 2 Server Installation
Figure 2-5. Accessing the Inside of the System
2-6 Checking the Drive Bay Setup
1. Accessing the drive bays
5. Supplying power to the system
2. DVD-ROM and floppy disk drives
3-1 Overview
Chapter System Interface
3-2 Control Panel Buttons
3-3 Control Panel LEDs
Figure 3-1. Universal Information LED States
3-4 SATA Drive Carrier LEDs
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Chapter System Safety
4-1 Electrical Safety Precautions
4-2 General Safety Precautions
4-3 ESD Precautions
4-4 Operating Precautions
Figure 4-1. Installing the Onboard Battery
Chapter Advanced Serverboard Setup
Precautions
5-1 Handling the Serverboard
Unpacking
5-2 Processor and Heatsink Installation
Installing the Processor
CPU installed in socket PnP cap released from load plate
Gold dot Socket key CPU key Notched corner CPU pin Load lever
Installing the Heatsink
Removing the Heatsink
Connecting Data Cables
5-3 Connecting Cables
Connecting Power Cables
Connecting the Control Panel
Figure 5-1. Front Control Panel Header Pins JF1
5-5 Installing Memory
DIMM Installation
5-4 I/O Ports
Figure 5-2. Rear Panel I/O Ports
Figure 5-3. Installing DIMM into Slot
Memory Support
5-6 Adding PCI Cards
2. PCI card installation
1. PCI Expansion Slots
PCI Slot/Card Configurations
5-7 Serverboard Details
Figure 5-4. SUPER PDSMU Layout
UPER
PDSMU
Default Setting
Connector
PDSMU Quick Reference
Jumper
5-8 Connector Definitions
ATX Power Connector
Processor Power Connector
Power LED
HDD LED
NIC1 LED
NIC2 LED
Universal Information LED
Power Fail LED
Reset Button
Power Button
Universal Serial Bus USB0/1
Universal Serial Bus Headers
Serial Ports
Fan Headers
Universal Serial Bus Headers Pin Definitions USB2/3, USB4/5
Speaker Connector
Chassis Intrusion
ATX PS/2 Keyboard and PS/2 Mouse Ports
Wake-On-LAN
Power SMB I2C Connector
Power Supply Fail
Alarm Reset JAR
Wake-On-Ring
LAN1/2 Ethernet Ports
Power LED
Power LED Pin Definitions JLED
Pin# Defi nition 1 +5V 2 Key 3 Ground
5-9 Jumper Settings
VGA Enable/Disable
Explanation of Jumpers
CMOS Clear
LAN Enable/Disable
Watch Dog Enable/Disable
Power Force On Enable/ Disable
LAN Enable/Disable Jumper Settings JPL1, JPL2
LAN1/LAN2 LEDs
5-10 Onboard Indicators
PWR-LED
Floppy Connector
5-11 Floppy, IDE and SATA Drive Connections
IDE Connector
SATA Ports
IDE Drive Connector Pin Definitions IDE#1
SATA Port Pin Definitions SATA0 ~ SATA3
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Chapter Advanced Chassis Setup
6-1 Static-Sensitive Devices
Tools Required
Precautions
6-2 Control Panel
Figure 6-1. Chassis Front and Rear Views
6-3 System Fans
System Fan Failure
Replacing System Fans
2. Installing a new fan
Removing the Front Bezel
6-4 Drive Bay Installation/Removal
Figure 6-2. System Cooling Fans
1. Unlock 2. Press release knob 3. Remove bezel assembly
Accessing the Drive Bays
Figure 6-3. Removing the Front Bezel
1. Mounting a SATA drive in a drive carrier
SATA Drive Installation
Figure 6-4. Mounting a SATA Drive in a Carrier
2. Installing/removing hot-swap SATA drives
Figure 6-5. Removing a SATA Drive from the Server
DVD-ROM and Floppy Drive Installation
6-5 Power Supply
Power Supply Failure
Removing/Replacing the Power Supply
5015M-UR/5015M-NTR
5015M-U/5015M-NT
Power Supply Failure
Removing/Replacing the Power Supply
1. Removing the power supply
Chapter 6 Advanced Chassis Setup
Figure 6-6. Removing/Replacing the Power Supply
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Chapter BIOS
System BIOS
How To Change the Configuration Data
Starting the Setup Utility
7-2 Running Setup
7-3 Main BIOS Setup
Default settings are in bold text unless otherwise noted
Press the Delete key to enter Setup
Main BIOS Setup Menu Main Setup Features
BIOS Date
System Time
System Date
Native Mode Operation
SATA Controller Mode
Serial ATA SATA RAID Enable
ICH RAID Code Base Available when SATA RAID is Enabled
LBA Mode Control
Transfer Mode
Ultra DMA Mode
Type
7-4 Advanced Setup
Boot Features
QuickBoot Mode
QuietBoot Mode
Power Loss Control
Memory Cache Cache System BIOS Area
Cache Video BIOS Area
Resume On Modem Ring
Reset Configuration Data
Cache Base 512K-640K
Cache Extended Memory
Discrete MTRR Allocation
Enable Master
Latency Timer
Large Disk Access Mode
Clock Spectrum Feature
USB Function
Legacy USB Support
Advanced Processor Options
CPU Speed
Intel R Virtualization Technology Available when supported by the CPU
No Execute Mode Memory Protection Available when supported by the
Set Maximum Extended CPUID=3
I/O Device Configuration
Serial Port A
Base I/O Address
Interrupt
Serial Port B
DMI Event Logging
Event Log Validity
Event Log Capacity
View DMI Event Log
Console Redirection
COM Port Address
BAUD Rate
Console Type
CPU Temperature Threshold
Hardware Monitor Logic
Voltage Monitoring
CPU Temperature/CPU Second Core Temperature System Temperature
Supervisor Password Is
User Password Is
Set Supervisor Password
Set User Password
Password on Boot
7-6 Boot
Boot Priority Order/Excluded from Boot Orders
Load Setup Defaults
7-7 Exit
Exit Saving Changes
Exit Discarding Changes
Appendix A BIOS POST Messages
Keyboard error
Keyboard locked - Unlock key switch
Monitor type does not match CMOS - Run SETUP
System CMOS checksum bad - Default configuration used
System timer error
Real time clock error
Check date and time settings
System cache error - Cache disabled
Fail-Safe Timer NMI Failed
Allocation Error for device
Entering SETUP
PS/2 Mouse Boot Summary Screen
Invalid System Configuration Data
I/O device IRQ conflict
nnnn kB Extended RAM Passed
Press F1 to resume, F2 to Setup, F3 for previous
Press F2 to enter Setup
System BIOS shadowed
Video BIOS shadowed
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Appendix B BIOS POST Codes
Recoverable POST Errors
Terminal POST Errors
POST Code
POST Code
8254 timer initialization
Description
Description
POST Code
Test RAM between 512 and 640 kB
Description
POST Code
Check for SMART Drive optional
The following are for boot block in Flash ROM
POST Code
Description
POST Code
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Intel HostRAID
C-1 Introduction to Serial ATA and Parallel ATA
Important Notes to the User
Serial ATA SATA
RAID Configurations
Configuring BIOS settings for SATA RAID Functions Native Mode
Intel Matrix Storage
Using the Intel ICH7R SATA RAID Utility Program
Creating a RAID 0 Volume
Creating a RAID 1 Volume
Creating a RAID 10 RAID 1+ RAID
Creating a RAID 5 Set Parity
Deleting a RAID Volume
Resetting to Non-RAID and Resetting a RAID HDD
Exiting the Intel Matrix Storage Manager Utility
C-2 Installing Windows XP/2000/2003 for RAID Systems
New Operating System-Windows XP/2000/2003 Installation
Appendix D Adaptec HostRAID Setup Guidelines
D-1 Introduction to the Intel ICH7R I/O Controller Hub
When Appropriate
Raid Level
Configuring the Adaptec SATA RAID
Using the Array Configuration Utility ACU
Using the Adaptec RAID Configuration Utility ARC
Adaptec Embedded SATA with HostRAID Controller Driver
Managing Arrays
Configuring Disk Drives
To configure a disk drive
Page
Appendix D Adaptec HostRAID Setup Guidelines
5. Read the warning message as shown in the screen below
Creating Arrays
To create an array
Assigning Array Properties
To assign properties to the new array
D-10
Deleting a Bootable Array
Adding a Bootable Array
D-11
D-12
Adding/Deleting Hotspares
D-13
Viewing Array Properties
D-14
Rebuilding Arrays
To Rebuild an array
Deleting Arrays
D-15
RAID 1 only-the following prompt is also displayed
To access the disk utilities
Using the Disk Utilities
D-16
D-17
To format a disk
D-18
To verify disk media
D-19
To Exit the Adaptec RAID Configuration Utility
D-2 Installing the Adaptec ICH7R Driver and the OS
D-20
BIOS
Appendix E System Specifications
Chipset
Memory Capacity
Weight
Power Supply
Serverboard
Chassis
Operating Environment
Regulatory Compliance