Manuals
/
SUPER MICRO Computer
/
Computer Equipment
/
Network Card
SUPER MICRO Computer
user manual SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Models:
5015M-U
5015M-UR
5015M-NT
5015M-NTR
1
58
134
134
Download
134 pages
15.96 Kb
55
56
57
58
59
60
61
62
<
>
Install
1. Intel 3010 Chipset System Block Diagram
Connecting Cables
Reset Button
Advanced Serverboard Setup
Unlock 2. Press release knob 3. Remove bezel assembly
Default Setting
Latency Timer
Jumper Settings
Ambient Operating Temperature
Page 58
Image 58
S
UPER
S
ERVER
5015M-UR/5015M-U/5015M-NTR/5015M-NT
User's Manual
Notes
5-24
Page 57
Page 59
Page 58
Image 58
Page 57
Page 59
Contents
SUPERSERVER 5015M-UR
1.0d
SUPER
SUPERSERVER 5015M-NTR SUPERSERVER 5015M-NT
Manual Revision 1.0d Release Date April 15
Printed in the United States of America
About This Manual
Chapter 2 Server Installation
Preface
Manual Organization
Chapter 6 Advanced Chassis Setup
Chapter 4 System Safety
Chapter 5 Advanced Serverboard Setup
Chapter 7 BIOS
Preface
Preface
Table of Contents
Chapter 2 Server Installation
Chapter 1 Introduction
Chapter 4 System Safety
Chapter 5 Advanced Serverboard Setup
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Appendices
Security
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Chapter Introduction
1-1 Overview
Memory
1-2 Serverboard Features
Processors
UIO 5015M-UR
System Power
1-3 Server Chassis Features
Other Features
Onboard Controllers/Ports
I/O Backplane
PCI Expansion Slots
Front Control Panel
Cooling System
CTRL
Figure 1-1. Intel 3010 Chipset System Block Diagram
ADDR
DATA
Europe
1-4 Contacting Supermicro
Headquarters
Asia-Pacific
2-1 Overview
Chapter Server Installation
2-3 Preparing for Setup
2-2 Unpacking the System
Rack Precautions
Warnings and Precautions
Choosing a Setup Location
Server Precautions
Reduced Airflow
Ambient Operating Temperature
Rack Mounting Considerations
Mechanical Loading
Identifying the Sections of the Rack Rails
2-4 Installing the System into a Rack
Installing the Inner Rails
Figure 2-1. Identifying the Sections of the Rack Rails
Figure 2-2. Installing the Rack Rails
Installing the Outer Rails
Locking Tabs
Installing the Server into the Rack
Figure 2-3. Installing the Server into a Rack
Installing the Server into a Telco Rack
Figure 2-4. Installing the Server into a Telco Rack
4. Installing add-on cards
2-5 Checking the Serverboard Setup
1. Accessing the inside of the system see Figure
2. Check the CPUs processors
Chapter 2 Server Installation
Figure 2-5. Accessing the Inside of the System
5. Supplying power to the system
2-6 Checking the Drive Bay Setup
1. Accessing the drive bays
2. DVD-ROM and floppy disk drives
3-1 Overview
Chapter System Interface
3-2 Control Panel Buttons
3-3 Control Panel LEDs
Figure 3-1. Universal Information LED States
3-4 SATA Drive Carrier LEDs
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Chapter System Safety
4-1 Electrical Safety Precautions
4-2 General Safety Precautions
4-3 ESD Precautions
4-4 Operating Precautions
Figure 4-1. Installing the Onboard Battery
5-1 Handling the Serverboard
Chapter Advanced Serverboard Setup
Precautions
Unpacking
5-2 Processor and Heatsink Installation
Installing the Processor
CPU installed in socket PnP cap released from load plate
Gold dot Socket key CPU key Notched corner CPU pin Load lever
Installing the Heatsink
Removing the Heatsink
Connecting Data Cables
5-3 Connecting Cables
Connecting Power Cables
Connecting the Control Panel
Figure 5-1. Front Control Panel Header Pins JF1
5-4 I/O Ports
5-5 Installing Memory
DIMM Installation
Figure 5-2. Rear Panel I/O Ports
Figure 5-3. Installing DIMM into Slot
Memory Support
1. PCI Expansion Slots
5-6 Adding PCI Cards
2. PCI card installation
PCI Slot/Card Configurations
UPER
5-7 Serverboard Details
Figure 5-4. SUPER PDSMU Layout
PDSMU
PDSMU Quick Reference
Default Setting
Connector
Jumper
Processor Power Connector
5-8 Connector Definitions
ATX Power Connector
Power LED
NIC2 LED
HDD LED
NIC1 LED
Universal Information LED
Power Button
Power Fail LED
Reset Button
Universal Serial Bus USB0/1
Fan Headers
Universal Serial Bus Headers
Serial Ports
Universal Serial Bus Headers Pin Definitions USB2/3, USB4/5
ATX PS/2 Keyboard and PS/2 Mouse Ports
Speaker Connector
Chassis Intrusion
Wake-On-LAN
Alarm Reset JAR
Power SMB I2C Connector
Power Supply Fail
Wake-On-Ring
Power LED Pin Definitions JLED
LAN1/2 Ethernet Ports
Power LED
Pin# Defi nition 1 +5V 2 Key 3 Ground
Explanation of Jumpers
5-9 Jumper Settings
VGA Enable/Disable
CMOS Clear
Power Force On Enable/ Disable
LAN Enable/Disable
Watch Dog Enable/Disable
LAN Enable/Disable Jumper Settings JPL1, JPL2
LAN1/LAN2 LEDs
5-10 Onboard Indicators
PWR-LED
Floppy Connector
5-11 Floppy, IDE and SATA Drive Connections
IDE Drive Connector Pin Definitions IDE#1
IDE Connector
SATA Ports
SATA Port Pin Definitions SATA0 ~ SATA3
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Tools Required
Chapter Advanced Chassis Setup
6-1 Static-Sensitive Devices
Precautions
6-2 Control Panel
Figure 6-1. Chassis Front and Rear Views
Replacing System Fans
6-3 System Fans
System Fan Failure
2. Installing a new fan
Removing the Front Bezel
6-4 Drive Bay Installation/Removal
Figure 6-2. System Cooling Fans
1. Unlock 2. Press release knob 3. Remove bezel assembly
Accessing the Drive Bays
Figure 6-3. Removing the Front Bezel
1. Mounting a SATA drive in a drive carrier
SATA Drive Installation
Figure 6-4. Mounting a SATA Drive in a Carrier
2. Installing/removing hot-swap SATA drives
Figure 6-5. Removing a SATA Drive from the Server
DVD-ROM and Floppy Drive Installation
Removing/Replacing the Power Supply
6-5 Power Supply
Power Supply Failure
5015M-UR/5015M-NTR
Removing/Replacing the Power Supply
5015M-U/5015M-NT
Power Supply Failure
1. Removing the power supply
Chapter 6 Advanced Chassis Setup
Figure 6-6. Removing/Replacing the Power Supply
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
How To Change the Configuration Data
Chapter BIOS
System BIOS
Starting the Setup Utility
Default settings are in bold text unless otherwise noted
7-2 Running Setup
7-3 Main BIOS Setup
Press the Delete key to enter Setup
System Time
Main BIOS Setup Menu Main Setup Features
BIOS Date
System Date
Serial ATA SATA RAID Enable
Native Mode Operation
SATA Controller Mode
ICH RAID Code Base Available when SATA RAID is Enabled
Ultra DMA Mode
LBA Mode Control
Transfer Mode
Type
QuickBoot Mode
7-4 Advanced Setup
Boot Features
QuietBoot Mode
Cache Video BIOS Area
Power Loss Control
Memory Cache Cache System BIOS Area
Resume On Modem Ring
Cache Extended Memory
Reset Configuration Data
Cache Base 512K-640K
Discrete MTRR Allocation
Large Disk Access Mode
Enable Master
Latency Timer
Clock Spectrum Feature
Advanced Processor Options
USB Function
Legacy USB Support
CPU Speed
Set Maximum Extended CPUID=3
Intel R Virtualization Technology Available when supported by the CPU
No Execute Mode Memory Protection Available when supported by the
I/O Device Configuration
Interrupt
Serial Port A
Base I/O Address
Serial Port B
Event Log Capacity
DMI Event Logging
Event Log Validity
View DMI Event Log
BAUD Rate
Console Redirection
COM Port Address
Console Type
Voltage Monitoring
CPU Temperature Threshold
Hardware Monitor Logic
CPU Temperature/CPU Second Core Temperature System Temperature
Set Supervisor Password
Supervisor Password Is
User Password Is
Set User Password
Password on Boot
7-6 Boot
Boot Priority Order/Excluded from Boot Orders
Exit Saving Changes
Load Setup Defaults
7-7 Exit
Exit Discarding Changes
Keyboard locked - Unlock key switch
Appendix A BIOS POST Messages
Keyboard error
Monitor type does not match CMOS - Run SETUP
Real time clock error
System CMOS checksum bad - Default configuration used
System timer error
Check date and time settings
Allocation Error for device
System cache error - Cache disabled
Fail-Safe Timer NMI Failed
Entering SETUP
I/O device IRQ conflict
PS/2 Mouse Boot Summary Screen
Invalid System Configuration Data
nnnn kB Extended RAM Passed
System BIOS shadowed
Press F1 to resume, F2 to Setup, F3 for previous
Press F2 to enter Setup
Video BIOS shadowed
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Terminal POST Errors
Appendix B BIOS POST Codes
Recoverable POST Errors
POST Code
POST Code
8254 timer initialization
Description
Description
POST Code
Test RAM between 512 and 640 kB
Description
POST Code
Check for SMART Drive optional
Description
The following are for boot block in Flash ROM
POST Code
POST Code
SUPERSERVER 5015M-UR/5015M-U/5015M-NTR/5015M-NT Users Manual
Important Notes to the User
Intel HostRAID
C-1 Introduction to Serial ATA and Parallel ATA
Serial ATA SATA
RAID Configurations
Configuring BIOS settings for SATA RAID Functions Native Mode
Intel Matrix Storage
Using the Intel ICH7R SATA RAID Utility Program
Creating a RAID 0 Volume
Creating a RAID 1 Volume
Creating a RAID 10 RAID 1+ RAID
Creating a RAID 5 Set Parity
Deleting a RAID Volume
Resetting to Non-RAID and Resetting a RAID HDD
Exiting the Intel Matrix Storage Manager Utility
C-2 Installing Windows XP/2000/2003 for RAID Systems
New Operating System-Windows XP/2000/2003 Installation
When Appropriate
Appendix D Adaptec HostRAID Setup Guidelines
D-1 Introduction to the Intel ICH7R I/O Controller Hub
Raid Level
Configuring the Adaptec SATA RAID
Using the Array Configuration Utility ACU
Using the Adaptec RAID Configuration Utility ARC
Adaptec Embedded SATA with HostRAID Controller Driver
Managing Arrays
Configuring Disk Drives
To configure a disk drive
Page
Appendix D Adaptec HostRAID Setup Guidelines
5. Read the warning message as shown in the screen below
Creating Arrays
To create an array
Assigning Array Properties
To assign properties to the new array
D-10
Deleting a Bootable Array
Adding a Bootable Array
D-11
D-12
Adding/Deleting Hotspares
D-13
Viewing Array Properties
D-14
Rebuilding Arrays
To Rebuild an array
Deleting Arrays
D-15
RAID 1 only-the following prompt is also displayed
To access the disk utilities
Using the Disk Utilities
D-16
D-17
To format a disk
D-18
To verify disk media
D-19
To Exit the Adaptec RAID Configuration Utility
D-2 Installing the Adaptec ICH7R Driver and the OS
D-20
Chipset
BIOS
Appendix E System Specifications
Memory Capacity
Serverboard
Weight
Power Supply
Chassis
Operating Environment
Regulatory Compliance
SUPERSERVER 5015M-UR/5015M-NT Users Manual